Publish in this journal
Journal Information
Vol. 42. Num. 5.June - July 2018
Pages e7-e12Pages 263-324
Vol. 42. Num. 5.June - July 2018
Pages e7-e12Pages 263-324
Images in Intensive Medicine
DOI: 10.1016/j.medine.2018.04.005
Full text access
Analysis of three cases of diffuse alveolar hemorrhage: False-negative results in pulmonary ultrasound
Análisis de 3 casos de hemorragia alveolar difusa: resultados falsos negativos en la ecografía pulmonar
Visits
188
L.A. Gorordo Delsola,
Corresponding author
luis.gorordodelsol@icloud.com

Corresponding author.
, A. Jiménez Ruizb, G.D. Hernández Lópeza
a Unidad de Cuidados Intensivos Adultos, Hospital Juárez de México, Mexico City, Mexico
b Servicio de Urgencias, IMSS Hospital General de Zona # 25 «Ignacio Zaragoza», Mexico City, Mexico
This item has received
188
Visits
Article information
Full Text
Download PDF
Statistics
Figures (1)
Full Text

We will be reviewing the cases of three (3) women hospitalized at one polyvalent ICU with a diagnosis of systemic erythematosus lupus (SEL) and diffuse alveolar hemorrhage (DAH). One point-of-care ultrasound device with a 3.5mHz convex transducer was used in the supine position with the patients’ heads inclined in a 30° angle and four (4) areas in each hemithorax were assessed, three (3) with mechanical ventilatory support. The lung pattern was “A” in the eight (8) areas assessed. Images 1A, 2A and 3A correspond to the Pulmonary ultrasound on right sector 3 (superior and lateral) and show the two-dimensional mode (B) with “A” lines and motion mode (M)–the “seashore” sign; panels B and C correspond to the simple CT scan and the X-ray (point-of-care, same position). The normal finding would be the alveolar-interstitial pattern with a great amount of “B” lines due to subpleural air entrapment in DAH and heterogeneous distribution, which leads to false negatives (Fig. 1).

Figure 1.
(0.33MB).

Please cite this article as: Gorordo Delsol LA, Jiménez Ruiz A, Hernández López GD. Análisis de 3 casos de hemorragia alveolar difusa: resultados falsos negativos en la ecografía pulmonar. Med Intensiva. 2018;42:e7–e8.

Copyright © 2016. Elsevier España, S.L.U. and SEMICYUC
Idiomas
Medicina Intensiva (English Edition)

Subscribe to our Newsletter

Article options
Tools
es en
Política de cookies Cookies policy
Utilizamos cookies propias y de terceros para mejorar nuestros servicios y mostrarle publicidad relacionada con sus preferencias mediante el análisis de sus hábitos de navegación. Si continua navegando, consideramos que acepta su uso. Puede cambiar la configuración u obtener más información aquí. To improve our services and products, we use "cookies" (own or third parties authorized) to show advertising related to client preferences through the analyses of navigation customer behavior. Continuing navigation will be considered as acceptance of this use. You can change the settings or obtain more information by clicking here.
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?