Journal Information
Vol. 42. Issue 3.
Pages 141-150 (April 2018)
Visits
5184
Vol. 42. Issue 3.
Pages 141-150 (April 2018)
Original
Full text access
Non-invasive ventilation in emergency departments in public hospitals in Catalonia. The VENUR-CAT study
Ventilación no invasiva en los servicios de urgencias hospitalarios públicos de Cataluña. Estudio VENUR-CAT
Visits
5184
J. Jacoba, J. Zorrillab,j, E. Genéc,j, G. Alonsod,j, P. Rimbaue, F. Casarramonaf, C. Nettog, P. Sánchezh, R. Hernándezh, X. Escaladah, Ò. Mirói,
Corresponding author
omiro@clinic.cat

Corresponding author.
a Servicio de Urgencias, Hospital Universitari de Bellvitge, IDIBELL, L’Hospitalet de Llobregat, Barcelona, Spain
b Servicio de Urgencias, Xarxa Assistencial de Manresa, Fundació Althaia, Manresa, Barcelona, Spain
c Servicio de Urgencias, Hospital Universitari Parc Taulí, Sabadell, Barcelona, Spain
d Servicio de Urgencias, Hospital General de Granollers, Granollers, Barcelona, Spain
e Servicio de Urgencias, Hospital Universitari Josep Trueta, Gerona, Spain
f Servicio de Urgencias, Hospital de Mataró, Mataró, Barcelona, Spain
g Servicio de Urgencias, Hospital Comarcal de Blanes, Corporació de Salut del Maresme i la Selva, Blanes, Gerona, Spain
h Sistema d’Emergencies Mèdiques (SEM), Spain
i Área de Urgencias, Hospital Clínic de Barcelona, Universitat de Barcelona, Barcelona, Spain
j Departamento de Medicina, Universitat Internacional de Catalunya, Barcelona, Spain
Ver más
Related content
Med Intensiva. 2018;42:139-4010.1016/j.medine.2017.05.007
F. Gordo, J. González del Castillo
This item has received
Article information
Abstract
Full Text
Bibliography
Download PDF
Statistics
Tables (4)
Table 1. Classification of the 52 public hospitals, ordered according to type, that participated in the study.
Table 2. Comparative study of professionals and training, according to the type of hospital, emergency care activity and the presence of an ICU.
Table 3. Comparative study of equipment and devices, according to the type of hospital, emergency care activity and the presence of an ICU.
Table 4. Comparative study of clinical scenarios and use, according to the type of hospital, emergency care activity and the presence of an ICU.
Show moreShow less
Abstract
Objectives

To know the implementation and characteristics of non-invasive ventilation (NIV) in the Emergency Departments (EDs) of public hospitals in Catalonia (Spain) and analyze possible differences based on the typology, degree of activity and the availability of an Intensive Care Unit (ICU) in the hospital.

Design

A non-interventional, descriptive study was carried out, using a structured questionnaire divided into 3 sections: 1) professional experience and training; 2) devices used; and 3) clinical scenarios and the use of NIV.

Setting

Persons responsible for public EDs in Catalonia.

Results

Fifty-two of the 54 public EDs in Catalonia responded (96.3%). Fifty-one perform NIV, which is mainly initiated by emergency care physicians (78.5%); 66.7% maintain the patient in the ED until discharge; and in 43.1% of the cases the length of stay is >24h. Of the EDs, 39.2% have their own protocol, 35.3% of which are established by consensus with other departments (more frequently in non-county hospitals [p=0.012], and centers with an ICU [p=0.014]), while 25.5% have no protocol, and 43.1% register the activity. Training represents the greatest difficulty for the implementation of NIV, but 19.6% do not provide specific training. When support is needed, the main physician of reference is the intensivist (35.3%) (more frequently in non-county hospitals [p=0.012], and centers with an ICU [p=0.002]).

Conclusions

In most EDs in Catalonia, NIV is performed by emergency care physicians. Areas needing improvement include drainage of patients once NIV has been started, the promotion of protocols, registry of activity, and training of the healthcare professionals.

Keywords:
Non-invasive ventilation
Critical care
Emergency care
Resumen
Objetivos

Conocer la implantación y características de la ventilación no invasiva (VNI) en los servicios de urgencias hospitalarios (SUH) públicos de Cataluña. Analizar si hay diferencias en función de la tipología, del grado de actividad y de la existencia de una unidad de cuidados intensivos (UCI) en el hospital.

Diseño

Estudio descriptivo, sin intervención, realizado mediante una encuesta estructurada en 3 bloques: 1) profesionales y formación; 2) aparataje utilizado y 3) escenarios clínicos y uso de la VNI.

Ámbito

Responsables de los SUH públicos de Cataluña.

Resultados

Contestaron 52 de 54 SUH públicos (96,3%): 51 realizan VNI, iniciada mayoritariamente por el médico de urgencias (78,5%). El 66,7% mantiene al paciente en urgencias hasta su retirada y en el 43,1% la estancia suele superar las 24h. El 39,2% de los SUH tienen un protocolo propio, el 35,3% consensuado con otros servicios (más en hospitales no comarcales, p=0,012, y con UCI, p=0,014) y el 25,5% no tiene. El 43,1% registran la actividad. El aprendizaje constituye la mayor dificultad para la implantación, pero el 19,6% no contempla la formación reglada regular. En caso de necesitar soporte, el principal médico de referencia es el especialista de Medicina Intensiva (35,3%, más en hospitales no comarcales, p=0,012, y con UCI, p=0,002).

Conclusiones

La VNI la realizan en la mayoría de los SUH los médicos de urgencias. Las áreas de mejora detectadas incluyen el drenaje de pacientes una vez iniciada la VNI, la potenciación de protocolos, el registro de actividad y la formación de los profesionales.

Palabras clave:
Ventilación no invasiva
Cuidados intensivos
Urgencias
Full Text
Introduction

Noninvasive ventilation (NIV) is essential in the management of acute respiratory failure.1 Evidence of the efficacy of NIV in different scenarios was first obtained in the 1990s from clinical trials and subsequently from meta-analyses, mostly conducted in Intensive Care Units (ICUs).2–6 The scenarios with the strongest scientific evidence and highest grade of recommendation in this regard are the exacerbation of chronic obstructive pulmonary disease (ECOPD)7 and acute heart failure (AHF).8

The use of NIV has subsequently spread to other care Units, and particularly to hospital Emergency Departments (EDs).9,10 A recent study has shown the most common scenario for the use of NIV in the ED to be AHF (38.0%), followed by ECOPD (34.2%).11 In Spain few studies offer information on the implementation of NIV and its characteristics in the ED. A study published in 2008 found NIV to be applied in 45.7% of the EDs,12 without specifying its implementation in the different Spanish Autonomous Communities, since the EDs in each Community were not detailed, and healthcare organization in Spain implies the possibility of differences among Communities. On the other hand, since 2008 the use of NIV has increased and has even reached the pre-hospital emergency care setting.13,14 In this context, the VENUR-CAT (Noninvasive ventilation in Emergency Departments in Catalonia [VENtilación no invasiva en URgencias en Cataluña]) study was designed with the purpose of knowing the implementation and characteristics of NIV in the EDs of public hospitals in Catalonia (Spain), the training of their professionals, and of analyzing possible differences based on the type of hospital, the degree of activity in the ED, and the availability of an ICU in the hospital.

Method

The VENUR-CAT study involved a non-interventional descriptive design based on a survey. The latter was developed by the research team during three successive meetings, giving rise to a 22-item questionnaire on NIV, divided into three blocks: one referred to the professionals and training; another addressing the equipment and devices used; and a third block referred to the clinical scenarios and utilization of NIV. The study sample comprised the persons in charge of the public EDs in Catalonia, which totaled 54 at the time of the study.15 The survey was sent by e-mail using the docs.google.com platform a total of 5 times between September and December 2016. Confidentiality of the individual data of the centers was maintained, and the participants were not asked to supply personal data of the professionals in the center. All the questions of the survey had to be answered, and once completed the questionnaire could not be repeated. The non-responders were contacted by telephone to complete the survey during January 2017. The project was approved by the Ethics Committee of Bellvitge University Hospital (code PR285/16).

The answers to the survey were individually tabulated in a database using the SPSS version 19.0 statistical package (IBM, North Castle, NY, USA). The hospitals were classified into three categories according to emergency care activity (high activity=over 200 visits a day; average activity=100–200 visits a day; low activity=under 100 visits a day), typology (HTH: high technology hospital, HRRH: high resolution reference hospital, RH: reference hospital, CH: county hospital), and the presence of absence of an ICU (Table 1).16 In order to facilitate comparisons, the research team established dichotomic groupings of the categories emergency care activity (high or average-low activity) and hospital typology (non-county hospital [NcH] or county hospital [CH]).

Table 1.

Classification of the 52 public hospitals, ordered according to type, that participated in the study.

Name of the hospital  Location  Type  Emergency care activity  ICU 
Hospital de la Vall d’Hebron  Barcelona  HTH  High  Yes 
Hospital Germans Trias i Pujol  Badalona  HTH  High  Yes 
Hospital Universitari de Bellvitge  L’Hospitalet de Llobregat  HTH  High  Yes 
Hospital de la Santa Creu i Sant Pau  Barcelona  HTH  High  Yes 
Hospital Clinic de Barcelona  Barcelona  HTH  High  Yes 
Hospital del Mar  Barcelona  HRRH  High  Yes 
Hospital Universitari Mútua de Terrassa  Terrasa  HRRH  High  Yes 
Consorsi Sanitari Parc Taulí  Sabadell  HRRH  High  Yes 
Hospital Universitari Arnau de Vilanova  Lérida  HRRH  High  Yes 
Hospital Universitari Joan XXIII de Tarragona  Tarragona  HRRH  High  Yes 
Hospital de Terrassa  Terrasa  HRRH  High  Yes 
Hospital CAPIO Sagrat Cor  Barcelona  HRRH  Average  Yes 
Hospital Josep Trueta de Girona  Gerona  HRRH  Average  Yes 
Hospital de Mataró  Mataró  RH  High  Yes 
Hospital General de Granollers  Granollers  RH  High  Yes 
Fundació Althaia Xarxa Assistencial Manresa  Manresa  RH  High  Yes 
Hospital Verge de la Cinta de Tortosa  Tortosa  RH  Average  Yes 
Hospital Residència Sant Camil  Sant Pere de Ribes  RH  Average  Yes 
Hospital Universitari Vic  Vic  RH  Average  Yes 
Hospital Sant Joan Despí Moisés Broggi  Sant Joan Despí  RH  Average  Yes 
Hospital General de L’Hospitalet  L’Hospitalet de Llobregat  RH  Average  Yes 
Hospital de Igualada  Igualada  RH  Average  Yes 
Parc Sanitari Sant Joan de Déu  Sant Boi de Llobregat  CH  High  Yes 
Hospital Sant Joan de Reus  Reus  CH  High  Yes 
Hospital del Vendrell  Vendrell  CH  High  No 
Hospital de Palamós  Palamós  CH  Average  No 
Hospital de Blanes  Blanes  CH  Average  No 
Hospital Sant Joan de Déu de Martorell  Martorell  CH  Average  No 
Hospital de Viladecans  Viladecans  CH  Average  No 
Hospital Santa Caterina  Salt  CH  Average  No 
Hospital de Figueres  Figueres  CH  Average  No 
Hospital Dos de Maig  Barcelona  CH  Average  No 
Pius Hospital de Valls  Valls  CH  Average  No 
Fundació Hospital Esperit Sant  Santa Coloma de Gramanet  CH  Average  No 
Hospital Sant Jaume Calella  Calella  CH  Average  No 
Hospital de Mollet  Mollet  CH  Average  No 
Hospital Sant Pau i Santa Tecla de Tarragona  Tarragona  CH  Average  No 
Hospital Comarcal de l’Alt Penedès  Vilafranca del Penedès  CH  Average  No 
Hospital Municipal de Badalona  Badalona  CH  Average  No 
Clínica Salus Infirmorum  Banyoles  CH  Low  No 
Hospital Plató  Barcelona  CH  Low  Yes 
Espitau Val d’Aran  Vielha  CH  Low  No 
Hospital Transfronterizo de Cerdanya  Cerdanya  CH  Low  No 
Hospital de Campdevànol  Campdevànol  CH  Low  No 
Hospital Comarcal del Pallars  Tremp  CH  Low  No 
Hospital Comarcal Sant Bernabé  Berga  CH  Low  No 
Hospital Comarcal de Móra d’Ebre  Móra d’Ebre  CH  Low  No 
Hospital Comarcal de Amposta  Amposta  CH  Low  No 
Fundació Sant Hospital  La Seu d’Urgell  CH  Low  No 
Clínica Terres de l’Ebre  Tortosa  CH  Low  No 
Hospital Comarcal de Sant Celoni  Sant Celoni  CH  Low  No 
Hospital Comarcal d’Olot  Olot  CH  Low  No 

HTH: high technology hospital; CH: county hospital; RH: reference hospital; HRRH: high resolution reference hospital: ICU: Intensive Care Unit.

The results corresponding to qualitative variables were reported as absolute values and percentages, while quantitative variables were expressed as the mean and standard deviation (SD) in the case of a normal distribution (as determined by the Kolmogorov–Smirnov test), or as the median and percentiles 25 and 75 (p25–75) in the case of a non-normal distribution. Comparisons between groups were made using the chi-squared test or applying the Fisher exact test for 2×2 contingency tables when the expected values were under 5 in the case of qualitative variables. One-way analysis of variance (ANOVA) or the Kruskal–Wallis test was used in the case of quantitative variables not exhibiting a normal distribution. In all cases statistical significance was considered for p<0.05.

Results

Fifty-two of the 54 EDs completed the survey (96.3% response rate). Noninvasive ventilation was used in 51 of them (98.1%). The supervisor of the only ED that did not use NIV intended to introduce the technique in future, though difficulties related to learning of the technique were expected.

With regard to the professionals and their training (Table 2), NIV was indicated and started by the emergency care physician in 78.5% of the EDs. Eighty percent of the staff physicians 50% of the physicians on duty performed the technique personally. The difficulties for implementing the process were the learning of the technique (84.9%), and a lack of collaboration on the part of the emergency care physicians (28.3%) and physicians from other hospital departments (24.5%). The need for ongoing training was cited by 96.1% of the supervisors, and this training was imparted in similar proportions in the ED and outside the hospital–though no training was recorded in 19.6% of the centers. There were no significant differences in any of these aspects according to the type of hospital, the presence or not of an ICU, or the volume of activity of the ED.

Table 2.

Comparative study of professionals and training, according to the type of hospital, emergency care activity and the presence of an ICU.

  Total n=51  NcH n=22  CH n=29  p  High n=17  Average/low n=34  p  With ICU n=25  Without ICU n=26  p 
Referred to ED and emergency care physicians n (%)
The physician in charge of performing NIV in the emergency care setting is:
Emergency care physician  40 (78.5)  17 (77.3)  23 (79.3)  1.000  14 (82.4)  26 (76.5)  0.731  19 (76)  21 (80.8)  0.679 
Specialist in Internal Medicine  4 (7.8)  0 (0)  4 (13.8)  0.124  0 (0)  4 (11.8)  0.288  0 (0)  4 (15.4)  0.110 
Intensivist  4 (7.8)  2 (9.1)  2 (6.9)  1.000  1 (5.9)  3 (8.8)  1.000  3 (12)  1 (3.8)  0.350 
Pneumologist  3 (5.9)  3 (13.6)  0 (0)  0.074  1 (2.9)  2 (11.8)  0.255  3 (12)  0 (0)  0.110 
Emergency staff physicians who perform NIV (%) [median (p25–75)]  80 (60–100)  80 (68–87)  75 (50–100)  1.000  80 (60–95)  75 (50–100)  0.489  80 (60–88)  78 (50–100)  1.000 
Only physicians on duty who perform NIV (%) [median (p25–75)]  50 (30–80)  80 (29–90)  50 (30–80)  0.338  55 (35–90)  50 (29–80)  0.487  80 (35–90)  50 (29–80)  0.217 
Implementation of the technique in emergency care is/was difficult  50 (98)  22 (100)  28 (96.6)  1.000  16 (94.1)  34 (100)  0.333  24 (96)  26 (100)  0.490 
There is/was implementation difficulty due to:
Technique learning process  45 (84.9)  17 (77.3)  28 (90.3)  0.253  13 (76.5)  32 (88.9)  0.252  19 (76)  25 (92.6)  0.134 
Lack of emergency care physician collaboration  15 (28.3)  5 (22.7)  10 (32.3)  0.448  5 (29.4)  10 (27.8)  1.000  5 (20)  9 (33.3)  0.279 
Lack of collaboration of other departments  13 (24.5)  7 (31.8)  6 (19.4)  0.299  5 (29.4)  8 (22.2)  0.734  8 (32)  4 (14.8)  0.142 
Referred to training aspects n (%)
Do you think training in NIV is necessary?
Yes, ongoing training  49 (96.1)  21 (95.5)  28 (96.6)  1.000  16 (94.1)  33 (97.1)  1.000  23 (92)  26 (100)  0.235 
Yes, but ongoing training is not needed  2 (3.9)  1 (4.5)  1 (3.4)  1.000  1 (5.9)  1 (2.9)  1.000  2 (8)  0 (0)  0.235 
Type of ongoing training for NIV in emergency care:                     
No protocolized training (accredited) contemplated  10 (19.6)  4 (18.2)  6 (20.7)  1.000  1 (5.9)  9 (26.5)  0.135  5 (20)  5 (19.2)  1.000 
Protocolized training (accredited) by the Emergency Department  12 (23.5)  4 (18.2)  8 (27.6)  0.433  3 (17.6)  9 (26.5)  0.728  4 (16)  8 (30.8)  0.214 
Protocolized training (accredited) outside the Emergency Department  15 (29.4)  8 (36.4)  7 (24.1)  0.343  6 (35.3)  9 (26.5)  0.514  8 (32)  7 (26.9)  0.691 
Protocolized training (accredited) in and outside the department  14 (27.5)  6 (27.3)  8 (27.6)  0.980  7 (41.2)  7 (20.6)  0.120  8 (32)  6 (23.1)  0.475 

CH: county hospital; NcH: non-county hospital; ED: hospital Emergency Department; ICU: Intensive Care Unit; NIV: noninvasive ventilation.

With regard to the equipment and devices used (Table 3), most of the EDs had their own means for performing NIV (88.2%), particularly specific turbine ventilators (84.3%). In turn, 84.3% of the EDs used the nasobuccal interface and 78.4% used both the continuous positive airway pressure (CPAP) and bi-level ventilation mode. Differences were found among the centers in terms of the type of respirator employed. In this respect, the specific ventilator was more prevalent in NcHs (100% versus 72.4%; p=0.007) and in hospitals with an ICU (100% versus 69.2%; p=0.003), as well as in centers with high emergency care activity (100% versus 76.5%; p=0.04). In contrast, invasive ventilation systems with NIV functions were more prevalent in CHs (65.5% versus 22.7%; p=0.001) and in centers without an ICU (65.4% versus 28%; p=0.007), as well as in hospitals with average/low emergency care activity (58.8% versus 23.5%; p=0.017).

Table 3.

Comparative study of equipment and devices, according to the type of hospital, emergency care activity and the presence of an ICU.

Referred to equipment and devices available in emergency care n (%)  Total n=51  NcH n=22  CH n=29  p  High n=17  Average/low n=34  p  With ICU n=25  Without ICU n=26  p 
The Emergency Department has its own NIV equipment  45 (88.2)  19 (86.4)  26 (89.7)  0.718  16 (94.1)  29 (85.3)  0.650  21 (84.0)  24 (92.3)  0.419 
No. of own NIV equipment units [median (p25-75)]  2 (1–3)  3 (1–4)  2 (1–3)  0.176  3 (2–4)  2 (1–3)  0.111  3 (1–4)  2 (1–3)  0.151 
Emergency care possesses:
Specific ventilator for NIV (turbines)  43 (84.3)  22 (100)  21 (72.4)  0.007  17 (100)  26 (76.5)  0.040  25 (100)  18 (69.2)  0.003 
Invasive ventilator allowing NIV  24 (47.1)  5 (22.7)  19 (65.5)  0.002  4 (23.5)  20 (58.8)  0.017  7 (28)  17 (65.4)  0.007 
Non-mechanical systems (e.g., CPAP Boussignac®12 (23.5)  5 (22.7)  7 (24.1)  0.906  4 (23.5)  8 (23.5)  1.000  5 (20)  7 (26.9)  0.560 
Nasobuccal interface  43 (84.3)  18 (81.8)  25 (86.2)  0.713  13 (76.5)  30 (88.2)  0.416  20 (80)  23 (88.5)  0.465 
Total face interface  20 (39.2)  10 (45.5)  10 (34.5)  0.427  7 (41.2)  13 (38.2)  0.839  11 (44)  9 (34.6)  0.493 
Type of interface used first in emergency care
Nasobuccal  43 (84.3)  18 (81.8)  25 (86.2)  0.713  13 (76.5)  30 (88.2)  0.416  20 (80)  23 (88.5)  0.465 
Total face  8 (15.7)  4 (18.2)  4 (13.8)  0.713  4 (23.5)  4 (11.8)  0.416  5 (20)  3 (11.5)  0.465 
NIV modes that can be used in emergency care
Only CPAP (continuous positive airway pressure)  1 (2)  0 (0)  1 (3.4)  1.000  0 (0.0)  1 (2.9)  1.000  0 (0)  1 (3.8)  1.000 
Only bi-level  10 (19.6)  5 (22.7)  5 (17.2)  0.728  5 (29.4)  5 (14.7)  0.270  5 (20)  5 (19.2)  1.000 
Both  40 (78.4)  17 (77.3)  23 (79.3)  1.000  12 (70.6)  28 (82.4)  0.472  20 (80)  20 (76.9)  0.789 

CH: county hospital; NcH: non-county hospital; ED: hospital Emergency Department; ICU: Intensive Care Unit; NIV: noninvasive ventilation.

Lastly, with regard to clinical scenarios and use (Table 4), 39.2% of the EDs had protocols of their own, 35.3% had protocols established by consensus with other departments, and 25.5% had no protocol. The indications in all the centers were AHF and ECOPD, and in 49% of the departments the technique was used in patients with limitations to advanced life support (LALS). A total of 66.7% of the ED supervisors informed that NIV was withdrawn in the ED, and that the use of the technique implied prolonged admission to the department (43.1% considered patient stay to exceed 24h). In turn, 68.8% responded that support was required from other specialists in relation to NIV. In these cases, the physician most often acting as reference was the intensivist (35.3%), followed by the specialist in Internal Medicine (19.6%). The comparison among centers showed protocols established by consensus with other departments to be more prevalent in NcHs (54.5% versus 20.7%; p=0.012) and in centers with an ICU (52% versus 19.2%; p=0.014). Likewise, the use of NIV in patients with LALS was more common in high activity EDs (70.6% versus 38.2%; p=0.029), and patients receiving NIV were more frequently admitted to Pneumology in high activity EDs (17.6% versus 0%; p=0.033) and remained more often in the ED in hospitals without an ICU (80.8% versus 52%; p=0.029). With regard to the supporting specialist, the intensivist was significantly more often involved in NcHs (54.5% versus 20.7%; p=0.012) and in centers with an ICU (56% versus 15.4%, p=0.002). In contrast, the specialist in Internal Medicine was more often involved in CHs (34.5% versus 0%; p=0.003), in centers without an ICU (38.5% versus 0%; p=0.001), and in average/low activity EDs (29.4% versus 0%; p=0.021).

Table 4.

Comparative study of clinical scenarios and use, according to the type of hospital, emergency care activity and the presence of an ICU.

Referred to clinical scenarios and use made in emergency care n (%)  Total n=51  NcH n=22  CH n=29  p  High n=17  Average/low n=34  p  With ICU n=25  Without ICU n=26  p 
There is a NIV protocol in emergency care:
No  13 (25.5)  6 (27.3)  7 (24.1)  0.799  4 (23.5)  9 (26.5)  1.000  7 (28)  6 (23.1)  0.687 
Yes, but exclusive of emergency care  20 (39.2)  4 (18.2)  16 (55.2)  0.007  5 (29.4)  15 (44.1)  0.311  5 (20)  15 (57.7)  0.006 
Yes, established by consensus with other departments  18 (35.3)  12 (54.5)  6 (20.7)  0.012  8 (47.1)  10 (29.4)  0.214  13 (52)  5 (19.2)  0.014 
Protocolized use in:
Exacerbated chronic obstructive pulmonary disease  51 (100)  22 (100)  29 (100)  –  17 (100)  34 (100)  –  25 (100)  26 (100)  – 
Acute lung edema secondary to acute heart failure  51 (100)  22 (100)  29 (100)  –  17 (100)  34 (100)  –  25 (100)  26 (100)  – 
Pneumonia in immune depressed patients  20 (39.2)  9 (40.9)  11 (37.9)  0.829  9 (52.9)  11 (32.4)  0.156  12 (48)  8 (30.8)  0.208 
Pneumonia in patients with preserved immune function  15 (29.4)  7 (31.8)  8 (27.6)  0.743  6 (35.4)  9 (26.5)  0.514  9 (36)  6 (23.1)  0.311 
Palliative cases  25 (49)  14 (63.6)  11 (37.9)  0.069  10 (58.8)  15 (44.1)  0.322  15 (60)  10 (38.5)  0.124 
Limitations to advanced life support in patients with orders not to intubate  25 (49)  12 (54.5)  13 (44.8)  0.492  12 (70.6)  13 (38.2)  0.029  15 (60)  10 (38.5)  0.124 
Clinical scenario with most frequent NIV use in emergency care
Exacerbated chronic obstructive pulmonary disease  38 (74.5)  16 (72.7)  22 (75.9)  0.799  5 (29.4)  8 (23.5)  0.738  7 (28)  6 (23.1)  0.687 
Acute lung edema secondary to acute heart failure  13 (25.5)  6 (27.3)  7 (24.1)  Id.  12 (70.6)  26 (76.5)  Id.  18 (72)  20 (76.9)  0.687 
Destination of patient with NIV from emergency care:
The patient remains in emergency care until suspension of NIV  34 (66.7)  11 (50)  23 (79.3)  0.028  12 (70.6)  22 (64.7)  0.674  13 (52)  21 (80.8)  0.029 
Internal Medicine  6 (11.8)  2 (9.1)  4 (13.8)  0.688  0 (0)  6 (17.6)  0.161  2 (8)  4 (15.4)  0.668 
Pneumology  3 (5.9)  3 (13.6)  0 (0)  0.074  3 (17.6)  0 (0)  0.033  3 (12)  0 (0)  0.110 
Intensive Care Medicine  4 (7.8)  3 (13.6)  1 (3.4)  0.303  1 (5.9)  3 (8.8)  1.000  4 (16)  0 (0)  0.051 
Intermediate care units  4 (7.8)  1 (3.4)  3 (13.6)  0.303  1 (5.9)  3 (8.8)  1.000  3 (12)  1 (3.8)  0.350 
Time during which the patient with NIV remains in emergency care:
Brief; the patient is moved to the destination unit on a priority basis  1 (2)  0 (0)  1 (3.4)  1.000  0 (0)  1 (2.9)  1.000  0 (0)  1 (3.8)  1.000 
Normal; the patient is moved to the destination unit on a non-priority basis  16 (31.3)  9 (40.9)  7 (24.1)  0.201  5 (29.4)  11 (32.4)  0.831  10 (40)  6 (23.1)  0.193 
Prolonged; NIV is often suspended in emergency care  34 (66.7)  13 (59.1)  21 (72.4)  0.318  12 (70.6)  22 (64.7)  0.674  15 (60)  19 (73.1)  0.322 
Hours during which the patient remains in emergency care with NIV:
Less than 127 (13.8)  2 (9.1)  5 (17.2)  0.684  1 (5.9)  6 (17.6)  0.250  2 (8)  5 (19.2)  0.419 
Between 12 and 2422 (43.1)  11 (50)  11 (37.9)  0.389  5 (29.4)  17 (50)  0.162  11 (44)  11 (42.3)  0.903 
Over 2422 (43.1)  9 (40.9)  13 (44.8)  0.780  11 (64.7)  11 (32.4)  0.028  12 (48)  10 (38.5)  0.492 
In the event support is needed, the reference physician is:
Support of other specialists is never needed  16 (31.4)  6 (27.3)  10 (34.5)  0.583  7 (41.2)  9 (26.5)  0.286  7 (28)  9 (34.6)  0.611 
Intensivist  18 (35.3)  12 (54.5)  6 (20.7)  0.012  6 (35.3)  12 (35.4)  1.000  14 (56)  4 (15.4)  0.002 
Specialist in Internal Medicine  10 (19.6)  0 (0)  10 (34.5)  0.003  0 (0)  10 (29.4)  0.021  0 (0)  10 (38.5)  0.001 
Pneumologist  7 (13.7)  4 (18.2)  3 (10.3)  0.447  4 (23.5)  3 (8.8)  0.203  4 (16)  3 (11.5)  0.703 
NIV activity is registered  22 (43.1)  12 (54.5)  10 (34.5)  0.152  7 (41.2)  15 (44.1)  0.842  13 (52)  9 (34.6)  0.210 

CH: county hospital; NcH: non-county hospital; ED: hospital Emergency Department; ICU: Intensive Care Unit; NIV: noninvasive ventilation.

Discussion

Noninvasive ventilation is performed in practically all EDs of public centers in Catalonia. This means that implementation of the technique, at least in this Autonomous Community, has been completed since the year 2008, when it was estimated that a little under one-half of all EDs in Spain used NIV (45.7%).12 This generalized implementation of NIV has undoubtedly been facilitated by technological advances in the ventilators, which are now more versatile and portable, thereby allowing them to be used in other settings such as pre-hospital emergency care and conventional hospital wards. A registry in patients with ECOPD has shown a significant increase in the use of NIV, from 1% in 1998 to 4.5% in 2008–with a concomitant decrease in invasive mechanical ventilation from 6% to 3.5% in the same period of time.17 Another registry involving 70 ICUs in France showed a significant increase in the use of NIV in different clinical scenarios over a period of only 5 years, from 16% in 1997 to 23% in 2002 (p<0.001).18 However, this increased use of NIV does not appear to be so significant in the case of AHF. In effect, the EAHFE registry, which analyzes 5845 episodes of AHF in three different periods, revealed an incidence of NIV utilization ranging from 3.2% in 2007 to 6% in 2009 and 4.5% in 2011 (p=0.24).19

Our data coincide with those published by Andreu-Ballester et al.12 in that the emergency care physician is the professional who generally performs NIV in the ED. We likewise coincide in the greater use of the nasobuccal interface, which offers important advantages in terms of convenience of use,20 and in the greater utilization of specific ventilators for performing NIV. This aspect is understandable: the current performance of these ventilators results in improved patient tolerance and effectively compensates air leakage, reducing asynchronies, improving the ventilator-patient relationship and thus ensuring increased success of the technique. The ICU ventilators designed for invasive ventilation in turn offer performances allowing them to be used also for NIV. Nevertheless, the difficulty of compensating leakage is an important limitation to the use of these systems–though such problems are increasingly less relevant thanks to the technological developments. A third category of ventilators has recently been introduced, offering shared performance (ICU ventilation and specific NIV) and allowing polyvalent use in different scenarios–particularly in relation to patient transfer.21 This would explain the increased presence of ICU ventilators in EDs of CHs and of hospitals with average or low activity, since they afford increased polyvalence, and in the event mechanical ventilation proves necessary the same ventilator can still be used.

Acute heart failure and ECOPD are the clinical scenarios in which NIV is most often used. In both cases the technique reduces patient mortality and the need for intubation. It therefore forms part of first line patient management, with a maximum level of evidence.9,10 In clinical practice it is in these scenarios where NIV proves most useful and offers greater patient benefit. In this respect, a survey of 132 EDs in the United States (with a 90% response rate) assessed NIV in three clinical scenarios–exacerbated asthma, ECOPD and AHF–and concluded that according to physician opinion, the technique is most useful in the latter two scenarios (p<0.001).22 Moreover, in these scenarios mortality is lower when compared with other NIV application settings,23 and this consequently inspires a degree of confidence among the professionals. Nevertheless, it must be remembered that the need for NIV identifies patients at increased risk of suffering adverse events.24

The management of patient stay is of great importance for EDs.25 In this regard, NIV is associated to prolonged admission: 86.2% of the EDs surveyed in our study reported a stay of over 12h, and in 66.7% of the cases NIV was suspended in the ED. The VNICat registry, involving the participation of 11 EDs in Catalonia, and which consecutively documented 159 NIV episodes during a one-month period in the ED, offers higher objective values, with an 83.1% incidence of NIV withdrawal in the ED. The authors associated this to deficiencies in management continuity of the technique.11 A study carried out in four Canadian hospitals and involving 618 patients requiring ventilatory support in the ED–484 invasive mechanical ventilation (78.3%), 118 NIV (19.1%), and 16 both (2.6%)–reported longer median stays in the ED among the patients subjected to NIV (16.6h, interquartile range [IQR]: 8.2–27.9) than in those subjected to mechanical ventilation alone (4.6h, IQR: 2.2–11.1) or both techniques (15.4h, IQR: 6.4–32.6). The authors attributed this difference in stay to the stabilization period usually seen in such patients, causing them to be left under observation and thus avoid needless admission to the ICU.26 This circumstance is even more notorious on considering that it is in the high activity hospitals of the VENUR-CAT study, where patient drainage should be more adequate, in which there are more patients with stays exceeding 24h. These are the centers where we find a greater percentage of patients subjected to LALS–the latter being a further reason underlying prolonged admission. In many hospitals, in situations of LALS, the patient is not considered a candidate for admission to the ICU, and is kept under observation in the ED. This practice is very debatable, however, since LALS should not be seen as a contraindication to ICU admission, though it can be understandable in the face of a progressively increasing ICU demand.27,28 This circumstance has already been described in the setting in which our study has been carried out, and the imbalance between ICU demand and number of available beds complicates early admission to intensive care, and can even imply that critical patients are unable to be admitted to the ICU–this situation in turn being associated to poorer prognostic outcomes.29

Our study describes a low incidence of NIV protocols established by consensus with other hospital departments. A possible solution to prolonged ED stay would be fluid communication and collaboration among the different participants in the NIV management process–this strategy having been shown to offer improved outcomes in other scenarios with use of the so-called lean method.30,31

Two aspects amenable to improvement are professional training and registry of the activity carried out. A large percentage of the responders in our study considered that difficulties implementing the technique are a consequence of problems associated to the learning process. If adequate training in the technique is not provided and knowledge of the technology is lacking, and an efficacy registry is moreover not kept, the impression is that NIV is of little help. In this regard, a survey of 46 Italian hospitals found the percentage registry of results to be very low (15%), and the perceived usefulness of the technique was poor, since 73% of those interviewed considered that NIV was able to avoid intubation in less than one-half of the cases.32 Another study by the same authors, involving nurses outside the ICU but who in principle could make use of NIV, found that only 13% considered training in NIV to be adequate, and pointed to the need for further training.33 The basic premise of NIV is to be well informed about the indications of the technique, how it is carried out, patient monitoring, ventilator technology and expendable materials use.34,35

The present study has several limitations. A first limitation refers to the method, since this is an opinion survey of the persons in charge of the EDs, who might not be involved in clinical practice, and therefore may have a less exact view of NIV than those involved in patient care. We consider that this does not constitute a major limitation, however, since these department supervisors are in charge of material resources, training organization, registries and protocols. Another possible limitation is that we have only considered public hospitals. In this regard, in Catalonia, private centers globally account for 16% of all ED consultations.16 We therefore are unable to analyze the situation referred to NIV use in these EDs. A further aspect not contemplated in our study is patient care continuity between the pre-hospital and the hospital setting, though implementation at hospital level in the studied setting is not very high.11

In conclusion, our study shows that NIV has been fully implemented in the public EDs of Catalonia, and that the technique is fundamentally performed by the emergency care physician, though there is room for organizational improvement closely related to the management of time and the continuity of patient care. The existence of protocols and support from the specialist in Internal Medicine is more prevalent in county hospitals and in centers with an ICU. More protocols established by consensus with other departments are needed in order to facilitate the transfer of these patients to the ICU or to intermediate care units in situations of prolonged NIV. Improved training efforts and activity registries are also needed.

Authorship/collaborations

Signing author contribution has been as follows:

  • Javier Jacob: design of the investigation, design of the survey questions, statistical analysis and drafting of the manuscript.

  • José Zorrilla: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Emili Gené: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Gilberto Alonso: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Pere Rimbau: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Francesc Casarramona: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Cristina Netto: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Pere Sánchez: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Ricard Hernández: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Xavier Escalada: design of the investigation, design of the survey questions and drafting of the manuscript.

  • Òscar Miró: design of the investigation, design of the survey questions, statistical analysis and drafting of the manuscript.

Conflict of interest

None.

Acknowledgements

Thanks are due to the supervisors of the Emergency Departments of Catalonia for their participation, and to Alicia Díaz for her field work in relation to the interviews. The present study received support from the Societat Catalana de Medicina d’Urgències i Emergències (SoCMUE) limited to covering the administrative costs of the survey.

References
[1]
S. Nava, N. Hill.
Non-invasive ventilation in acute respiratory failure.
[2]
L. Brochard, J. Mancebo, M. Wysocki, F. Lofaso, G. Conti, A. Raus, et al.
Noninvasive ventilation for acute exacerbations of chronic obstructive pulmonary disease.
N Engl J Med, 333 (1995), pp. 817-822
[3]
S.P. Keenan, P.D. Kernerman, D.J. Cook, C.M. Martín, D. McCormack, W.J. Sibbald.
Effect of noninvasive positive pressure ventilation on mortality in patients admitted with acute respiratory failure: a meta-analysis.
Crit Care Med, 25 (1997), pp. 1689-1692
[4]
A. Mas, J. Masip.
Noninvasive ventilation in acute respiratory failure.
Int J Chron Obstruct Pulmon Dis, 11 (2014), pp. 837-852
[5]
J. Masip, A.J. Betbesé, J. Páez, F. Vecilla, R. Cañizares, J. Padró, et al.
Non-invasive pressure support ventilation versus conventional oxygen therapy in acute cardiogenic pulmonary oedema: a randomised trial.
Lancet, 356 (2000), pp. 2126-2132
[6]
J. Masip, M. Roque, B. Sánchez, R. Fernández, M. Subirana, J.A. Expósito.
Noninvasive ventilation in acute cardiogenic pulmonary edema: systematic review and metaanalysis.
JAMA, 294 (2005), pp. 3124-3130
[7]
F.S. Ram, J. Picot, J. Lightowler, J.A. Wedzicha.
Non-invasive positive pressure ventilation for treatment of respiratory failure due to exacerbations of chronic obstructive pulmonary disease.
Cochrane Database Syst Rev, 1 (2004),
CD004104
[8]
F.M. Vital, M.T. Ladeira, A.N. Atallah.
Non-invasive positive pressure ventilation (CPAP or bilevel NPPV) for cardiogenic pulmonary oedema.
Cochrane Database Syst Rev, 5 (2013),
CD005351
[9]
J.A. Sánchez-Nicolás, C. Cinesi-Gómez, T. Villén-Villegas, P. Piñera-Salmerón, B. García-Pérez.
Relación entre la movilidad diafragmática medida por ecografía y la presión parcial arterial de CO2 en pacientes con insuficiencia respiratoria aguda hipercápnica tras el inicio de la ventilación mecánica no invasiva en urgencias.
Emergencias, 28 (2016), pp. 345-348
[10]
M. Fernández González, R.L. García-Mayor Fernández.
Ventilación mecánica no invasiva en un paciente politraumatizado con insuficiencia respiratoria aguda secundaria a una atelectasia masiva.
Emergencias, 28 (2016), pp. 140
[11]
J. Jacob, M. Arranz, M. Sancho Ramoneda, A. López, M.C. Navarro Sáez, J.R. Cousiño Chao, et al.
Estudio de cohortes de pacientes tratados con ventilación no invasiva en servicios de urgencias prehospitalarios y hospitalarios de Cataluña: Registro VNICat.
Emergencias, 29 (2017), pp. 33-38
[12]
J.C. Andreu-Ballester, A. Almela-Quilis, M.J. Cano-Cano, R. Sorando, A. Dolz-Domingo, E. Gonzalvo-Bellver, et al.
Use of non-invasive positive pressure ventilation in emergency departments of hospitals in Spain.
Emerg Med J, 27 (2010), pp. 619-620
[13]
J. Thompson, D.A. Petrie, S. Ackroyd-Stolarz, D.J. Bardua.
Out-of-hospital continuous positive airway pressure ventilation versus usual care in acute respiratory failure: a randomized controlled trial.
Ann Emerg Med, 52 (2008), pp. 232-241
[14]
S. Mal, S. McLeod, A. Iansavichene, A. Dukelow, M. Lewell.
Effect of out-of-hospital noninvasive positive-pressure support ventilation in adult patients with severe respiratory distress: a systematic review and meta-analysis.
Ann Emerg Med, 63 (2014), pp. 600-607
[15]
Ministerio de Sanidad, Servicios Sociales e Igualdad. Catálogo Nacional de Hospitales 2012. Available from: http://www.msssi.gob.es/ciudadanos/prestaciones/centrosServiciosSNS/hospitales/docs/CNH2012.pdf [accessed 11.09.13].
[16]
O. Miró, X. Escalada, E. Gené, C. Boqué, F.X. Jiménez Fábrega, C. Netto, et al.
Estudio SUHCAT (1): mapa físico de los servicios de urgencias hospitalarios de Cataluña.
Emergencias, 26 (2014), pp. 19-34
[17]
D. Chandra, J.A. Stamm, B. Taylor, R.M. Ramos, L. Satterwhite, J.A. Krishnan, et al.
Outcomes of noninvasive ventilation for acute exacerbations of chronic obstructive pulmonary disease in the United States, 1998–2008.
Am J Respir Crit Care Med, 185 (2012), pp. 152-159
[18]
A. Demoule, E. Girou, J.C. Richard, S. Taillé, L. Brochard.
Increased use of noninvasive ventilation in French intensive care units.
Intensive Care Med, 32 (2006), pp. 1747-1755
[19]
P. Llorens, R. Escoda, O. Miró, P. Herrero-Puente, F.J. Martín-Sánchez, J. Jacob, et al.
Características clínicas, terapéuticas y evolutivas de los pacientes con insuficiencia cardiaca aguda atendidos en servicios de urgencias españoles: Registro EAHFE (Epidemiology of Acute Heart Failure in Spanish Emergency Departments).
Emergencias, 27 (2015), pp. 11-22
[20]
H. Kwok, J. McCormack, R. Cece, J. Houtchens, N.S. Hill.
Controlled trial of oronasal versus nasal mask ventilation in the treatment of acute respiratory failure.
Crit Care Med, 31 (2003), pp. 468-473
[21]
R. Scala, M. Naldi.
Ventilators for noninvasive ventilation to treat acute respiratory failure.
Respir Care, 53 (2008), pp. 1054-1080
[22]
D.R. Hess, J.M. Pang, C.A. Camargo Jr..
A survey of the use of noninvasive ventilation in academic emergency departments in the United States.
Respir Care, 54 (2009), pp. 1306-1312
[23]
F. Martín-González, J. González-Robledo, F. Sánchez-Hernández, N.M. Moreno-García, I. Barreda-Mellado.
Efectividad y predictores de fracaso de la ventilación mecánica no invasiva en la insuficiencia respiratoria aguda.
Med Intensiva, 40 (2016), pp. 9-17
[24]
J. Jacob, Ò. Miró, P. Herrero, F.J. Martín-Sánchez, V. Gil, J. Tost, et al.
La predicción de mortalidad a corto plazo en pacientes con exacerbación aguda de la insuficiencia cardiaca crónica: la EAHFE escala -3D.
Med Intensiva, 40 (2016), pp. 348-355
[25]
L.F. Lobón, P. Anderson.
Innovación en Medicina de Urgencias y Emergencias: cinco aspectos organizativos que podrían cambiar nuestra práctica.
Emergencias, 29 (2017), pp. 61-64
[26]
L. Rose, S. Gray, K. Burns, C. Atzema, A. Kiss, A. Worster, et al.
Emergency department length of stay for patients requiring mechanical ventilation: a prospective observational study.
Scand J Trauma Resusc Emerg Med, 20 (2012), pp. 30
[27]
A. Hernández-Tejedora, M.C. Martín Delgado, L. Cabré Pericas, A. Algora Webera.
Limitación del tratamiento de soporte vital en pacientes con ingreso prolongado en UCI. Situación actual en España a la vista del Estudio EPIPUSE.
Med Intensiva, 39 (2015), pp. 395-404
[28]
T. Mozo Martín, F. Gordo Vidal.
Innovación en la gestión de las unidades de cuidados intensivos: es el momento.
Med Intensiva, 40 (2016), pp. 263-352
[29]
R. Fernandez.
Ocupación de los Servicios de Medicina Intensiva de Catalunya: un estudio analítico prospectivo de cohortes.
Med Intensiva, 39 (2015), pp. 537-542
[30]
M. Sánchez Sánchez.
Lean healthcare en los servicios de urgencias hospitalarios. ¿Ha venido para quedarse?.
Emergencias, 26 (2014), pp. 81-83
[31]
J.M. Sirvent, M. Gil, T. Álvarez, S. Martín, N. Vila, M. Colomer, et al.
Técnicas «Lean» para la mejora del flujo de los pacientes críticos de una región sanitaria con epicentro en el servicio de medicina intensiva de un hospital de referencia.
Med Intensiva, 40 (2016), pp. 266-272
[32]
L. Cabrini, M. Antonelli, G. Savoia, M. Landriscina.
Non-invasive ventilation outside of the intensive care unit: an Italian survey.
Minerva Anestesiol, 77 (2011), pp. 313-322
[33]
L. Cabrini, G. Monti, M. Villa, A. Pischedda, L. Masini, E. Dedola, et al.
Non-invasive ventilation outside the intensive care unit for acute respiratory failure: the perspective of the general ward nurses.
Minerva Anestesiol, 75 (2009), pp. 427-433
[34]
M.W. Elliott, M. Confalonieri, S. Nava.
Where to perform noninvasive ventilation.
Eur Respir J, 19 (2002), pp. 1159-1166
[35]
C. Lorencio, J.M. Sirvent.
Ventilación no invasiva: ¿cuándo, cómo y dónde?.
Med Intensiva, 36 (2012), pp. 601-603

Please cite this article as: Jacob J, Zorrilla J, Gené E, Alonso G, Rimbau P, Casarramona F, et al. Ventilación no invasiva en los servicios de urgencias hospitalarios públicos de Cataluña. Estudio VENUR-CAT. Med Intensiva. 2018;42:141–150.

Copyright © 2017. Elsevier España, S.L.U. and SEMICYUC
Idiomas
Medicina Intensiva (English Edition)
Article options
Tools
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?