Medicina Intensiva Medicina Intensiva
Med Intensiva 2017;41:270-6 - Vol. 41 Núm.5 DOI: 10.1016/j.medin.2016.07.008
ORIGINAL
Evaluación del conocimiento y de las habilidades para el uso de un Desfibrilador Externo Automatizado (DEA) por estudiantes universitarios. Un diseño cuasiexperimental
Assessment of knowledge and skills in using an Automated External Defibrillator (AED) by university students. A quasi-experimental study
S. Basanta Camiñoa, R. Navarro Patóna,, , M. Freire Telladob, R. Barcala Furelosc, M.P. Pavón Prietob, M. Fernández Lópezb, M.A. Neira Pájarod
a Facultad de Formación del Profesorado, Universidad de Santiago de Compostela, Lugo, España
b Servicio de Emergencias Médicas de la Fundación Pública Urgencias Sanitarias 061, Base 061 Lugo, Centro de Salud de Fingoy, Lugo, España
c Facultad de Ciencias de la Educación y del Deporte, Universidad de Vigo, Campus A Xunqueira, Pontevedra, España
d Fundación Pública Urgencias Sanitarias 061, Base 061 Foz, Foz, Lugo, España
Recibido 04 mayo 2016, Aceptado 31 julio 2016
Resumen
Objetivo

Evaluar la capacidad del personal lego (estudiantes universitarios) para usar un desfibrilador externo automatizado (DEA).

Diseño

Estudio cuasiexperimental de medidas repetidas de muestreo no probabilístico con grupo control.

Ámbito

Estudiantes de formación de profesorado de la Universidad de Santiago de Compostela.

Participantes

La muestra estuvo compuesta por 129 sujetos, 69% mujeres y 31% hombres, de entre 19 y 47 años (media 23,2±4,7), cuyo criterio de inclusión fue el no tener conocimientos previos sobre DEA.

Intervenciones

Se tomaron los tiempos empleados en aplicar una descarga sobre un maniquí con DEA sin formación (T0); tras una explicación teórico-práctica inferior a 1 minuto (T1) y tras 6 meses del proceso formativo (T2).

Variables de interés principales

La variable de resultado principal fue el tiempo empleado en aplicar una descarga. Se definió la variable «efecto de mejora» mediante la diferencia absoluta de tiempo entre T1 y T0, y la variable «efecto de grado de olvido» como la diferencia absoluta entre T1 y T2.

Resultados

Las medias de tiempos fueron: T0=67,7s; T1=44,2s; T2=45,9s. Se redujo el tiempo para realizar una descarga tras la explicación formativa (T1<T0) (−23,4s; p<0,001). El T2 es inferior a T0 (−21,8s; p<0,001), pero mayor que T1 (1,6s; p=0,002). El efecto de mejora fue significativo (p<0,001), al igual que el grado de olvido (p=0,002).

Conclusiones

Se demostró el fácil manejo del DEA, ya que personas sin formación fueron capaces de aplicar una descarga. El tiempo de administración de descarga se redujo tras una pequeña formación. Este tiempo apenas aumentó pasados 6 meses.

Abstract
Aim

To evaluate layperson (university student) ability to use an automated external defibrillator (AED).

Design

A repeated measures quasi-experimental study with non-probabilistic sampling and a control group was carried out.

Scope

Teacher training degree students at the University of Santiago de Compostela (Spain).

Participants

The sample consisted of 129 subjects (69% women and 31% men), between 19-47 years of age (mean 23.2±4.7 years). As inclusion criterion, the subjects were required to have no previous knowledge of AED.

Interventions

Times to apply defibrillation with an AED to a mannequin were recorded untrained (T0), after a theoretical and practice explanation lasting less than one minute (T1), and 6 months after the training process (T2).

Main variables of interest

The primary endpoint was the time taken to deliver a defibrillation discharge. The “improvement effect” variable was defined by the absolute time difference between T1 and T0, while the “degree of forgetfulness effect” variable was defined as the absolute difference between T1 and T2.

Results

The mean times were T0=67.7s; T1=44.2s; T2=45.9s. The time to apply defibrillation was reduced after explanation training (T1<T0) (−23.4s; P<.001). T2 proved shorter than T0 (−21.8s; P<.001) but longer than T1 (1.6s; P=.002). The improvement effect was significant (P<.001), in the same way as the degree of forgetfulness (P=.002).

Conclusions

Easy handling of AED was demonstrated, since untrained people were able to deliver a discharge. Defibrillation time was reduced after brief training. This time barely increased after 6 months.

Palabras clave
Personal lego, Desfibrilador externo automatizado, Primer interviniente
Keywords
Laypersons, Automated external defibrillator, First responder

Artículo

Para acceder a los textos completos de la publicación Medicina Intensiva es necesario ser suscriptor o miembro de la Sociedad Española de Medicina Intensiva, Crítica y Unidades Coronarias.

  • Si es usted socio de la Sociedad Española de Medicina Intensiva, Crítica y Unidades Coronarias:
    Diríjase al área de socios de la web de la SEMICYUC (www.semicyuc.org ) y pulse el enlace a la revista.
  • Si usted es suscriptor:
    Puede usted recuperar sus datos en la sección "Olvidé la contraseña" situado en la barra lateral derecha de este sitio web.

Med Intensiva 2017;41:270-6 - Vol. 41 Núm.5 DOI: 10.1016/j.medin.2016.07.008