array:19 [
  "pii" => "13055982"
  "issn" => "02105691"
  "estado" => "S300"
  "fechaPublicacion" => "2003-12-01"
  "documento" => "article"
  "crossmark" => 0
  "subdocumento" => "fla"
  "cita" => "Med Intensiva. 2003;27:673-5"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 20925
    "formatos" => array:3 [
      "EPUB" => 210
      "HTML" => 15256
      "PDF" => 5459
    ]
  ]
  "itemSiguiente" => array:15 [
    "pii" => "13055983"
    "issn" => "02105691"
    "estado" => "S300"
    "fechaPublicacion" => "2003-12-01"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "Med Intensiva. 2003;27:676-85"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 15071
      "formatos" => array:3 [
        "EPUB" => 158
        "HTML" => 12903
        "PDF" => 2010
      ]
    ]
    "es" => array:11 [
      "idiomaDefecto" => true
      "titulo" => "Coagulación y hemorragia en el paciente crítico. Parte II. Factor pronóstico y tratamiento"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "tieneResumen" => array:2 [
        0 => "es"
        1 => "en"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "676"
          "paginaFinal" => "685"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "Coagulation and hemorrhage in the critically-ill. patient Part II. Prognostic factor and treatment"
        ]
      ]
      "contieneResumen" => array:2 [
        "es" => true
        "en" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "M Quintana Díaz, D Cabestrero Alonso, A García de Lorenzo y Mateos"
          "autores" => array:3 [
            0 => array:2 [
              "Iniciales" => "M"
              "apellidos" => "Quintana Díaz"
            ]
            1 => array:2 [
              "Iniciales" => "D"
              "apellidos" => "Cabestrero Alonso"
            ]
            2 => array:2 [
              "Iniciales" => "A"
              "apellidos" => "García de Lorenzo y Mateos"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/13055983?idApp=WMIE"
    "url" => "/02105691/0000002700000010/v0_201212111616/13055983/v0_201212111617/es/main.assets"
  ]
  "itemAnterior" => array:15 [
    "pii" => "13055981"
    "issn" => "02105691"
    "estado" => "S300"
    "fechaPublicacion" => "2003-12-01"
    "documento" => "article"
    "crossmark" => 0
    "subdocumento" => "fla"
    "cita" => "Med Intensiva. 2003;27:669-72"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 2698
      "formatos" => array:3 [
        "EPUB" => 114
        "HTML" => 1891
        "PDF" => 693
      ]
    ]
    "es" => array:9 [
      "idiomaDefecto" => true
      "titulo" => "¿Qué podríamos hacer para mejorar los resultados en el traumatizado grave?"
      "tienePdf" => "es"
      "tieneTextoCompleto" => "es"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "669"
          "paginaFinal" => "672"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "en" => array:1 [
          "titulo" => "What can we do to improve outcomes in severe trauma?"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "es" => true
      ]
      "contienePdf" => array:1 [
        "es" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "F Murillo-Cabezas, MA Muñoz-Sánchez"
          "autores" => array:2 [
            0 => array:2 [
              "Iniciales" => "F"
              "apellidos" => "Murillo-Cabezas"
            ]
            1 => array:2 [
              "Iniciales" => "MA"
              "apellidos" => "Muñoz-Sánchez"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "es"
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/13055981?idApp=WMIE"
    "url" => "/02105691/0000002700000010/v0_201212111616/13055981/v0_201212111616/es/main.assets"
  ]
  "es" => array:10 [
    "idiomaDefecto" => true
    "titulo" => "Ventilación mecánica en pediatría. ¿Cómo y cuándo extubar?"
    "tieneTextoCompleto" => true
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "673"
        "paginaFinal" => "675"
      ]
    ]
    "autores" => array:1 [
      0 => array:3 [
        "autoresLista" => "A Martínez de Azagra, J Casado Flores, R Jiménez García"
        "autores" => array:3 [
          0 => array:3 [
            "Iniciales" => "A"
            "apellidos" => "Martínez de Azagra"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "affa"
              ]
            ]
          ]
          1 => array:3 [
            "Iniciales" => "J"
            "apellidos" => "Casado Flores"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "affa"
              ]
            ]
          ]
          2 => array:3 [
            "Iniciales" => "R"
            "apellidos" => "Jim&#233;nez Garc&#237;a"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "affa"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:1 [
          0 => array:3 [
            "entidad" => "Servicio de Cuidados Intensivos. Hospital Universitario Niño Jesús. Universidad Autónoma de Madrid. Madrid. España."
            "etiqueta" => "<span class="elsevierStyleSup">a</span>"
            "identificador" => "affa"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "Mechanical ventilation in pediatrics&#46; How and when to extubate&#63;"
      ]
    ]
    "textoCompleto" => "<p class="elsevierStylePara">La ventilaci&#243;n mec&#225;nica es una t&#233;cnica absolutamente necesaria en el soporte vital de muchos ni&#241;os&#59; sin embargo implica importantes riesgos y complicaciones&#46; El destete del respirador o <span class="elsevierStyleItalic">weaning</span> es el proceso de retirada de la ventilaci&#243;n mec&#225;nica y es&#44; por tanto&#44; un per&#237;odo de transici&#243;n entre la respiraci&#243;n artificial y la espont&#225;nea&#46;</p><p class="elsevierStylePara">El objetivo del destete es ayudar al paciente a recuperar la respiraci&#243;n espont&#225;nea en el menor tiempo posible y prevenir as&#237; las complicaciones de una ventilaci&#243;n mec&#225;nica prolongada sin incurrir en un riesgo demasiado alto de reintubaci&#243;n&#46;</p><p class="elsevierStylePara">Las preguntas clave ante el ni&#241;o con ventilaci&#243;n mec&#225;nica son&#58; <span class="elsevierStyleItalic">1&#41;</span> c&#243;mo y cu&#225;ndo iniciar el destete&#44; y <span class="elsevierStyleItalic">2&#41;</span> cu&#225;les son los predictores de &#233;xito o fracaso de la desconexi&#243;n del respirador&#46;</p><p class="elsevierStylePara"> Mientras que en adultos existen numerosos estudios<span class="elsevierStyleSup">1&#44;2</span> que avalan el seguimiento de protocolos espec&#237;ficos para realizar el destete del respirador&#44; en pediatr&#237;a existen pocos trabajos<span class="elsevierStyleSup">3-5</span> que valoren el modo de realizarlo&#44; y los que existen llegan conclusiones diferentes&#46;</p><p class="elsevierStylePara"> Randolph et al<span class="elsevierStyleSup">3</span>&#44; en un trabajo denominado <span class="elsevierStyleItalic">Effect of mechanical ventilation weaning protocols on<br></br> respiratory outcomes in infants and children&#44;</span> comparan la realizaci&#243;n del destete seg&#250;n protocolo con el destete basado en la experiencia cl&#237;nica&#46; Los objetivos fundamentales de este estudio fueron&#58; <span class="elsevierStyleItalic">1&#41;</span> evaluar si el seguimiento de un protocolo de destete obten&#237;a mejores resultados que el realizado de forma estandarizada&#44; y <span class="elsevierStyleItalic">2&#41;</span> si un determinado protocolo &#40;volumen soporte&#41; era mejor que otro &#40;presi&#243;n soporte&#41; para alcanzar el objetivo de la extubaci&#243;n&#46; Como objetivos secundarios se plantearon evaluar la aplicaci&#243;n de criterios de predicci&#243;n de &#233;xito o fracaso de la extubaci&#243;n y estudiar la influencia de la sedaci&#243;n recibida durante el procedimiento sobre los resultados&#46;</p><p class="elsevierStylePara">Se trata de un estudio prospectivo multic&#233;ntrico en el que los autores incluyeron a aquellos ni&#241;os &#40;desde reci&#233;n nacidos con edad gestacional &#62; 38 semanas hasta 18 a&#241;os&#41; que precisaron ventilaci&#243;n mec&#225;nica durante m&#225;s de 24 h&#46; Los autores excluyeron todos los pacientes que presentaron alteraciones cong&#233;nitas o adquiridas de la v&#237;a a&#233;rea superior&#44; hernia o par&#225;lisis diafragm&#225;tica&#44; hipertensi&#243;n pulmonar&#44; pacientes que precisaban respirador o ventilaci&#243;n no invasiva en su situaci&#243;n basal&#44; capacidad pulmonar disminuida&#44; cardiopat&#237;a cong&#233;nita cian&#243;tica&#44; trasplante de m&#233;dula &#243;sea&#44; traumatismo espinal o patolog&#237;a neuromuscular&#46; Fueron excluidos 1&#46;597 pacientes de un total de 2&#46;349&#46; De los 752 pacientes restantes&#44; 439 no fueron incluidos por falta de consentimiento&#44; traslado a otros hospitales&#44; no disponibilidad de equipo u otros motivos&#44; y fueron definitivamente incluidos en el estudio 313 pacientes &#40;12&#44;8&#37; de los pacientes ventilados&#41;&#46;</p><p class="elsevierStylePara">Los autores consideraron&#44; de acuerdo a la experiencia previa<span class="elsevierStyleSup">6&#44;7</span>&#44; que muchos de los ni&#241;os no requer&#237;an un descenso progresivo de la asistencia y pod&#237;an ser extubados directamente&#46; A &#233;stos se les someti&#243; a un test de extubaci&#243;n basado en presi&#243;n soporte&#46;</p><p class="elsevierStylePara">Los criterios para realizar el test de extubaci&#243;n fueron los siguientes&#58; FiO<span class="elsevierStyleInf">2</span> &#8804; 0&#44;6&#59; presi&#243;n positiva espiratoria final &#40;PEEP&#41; &#8804; 7 cmH<span class="elsevierStyleInf">2</span>O&#59; esfuerzo respiratorio espont&#225;neo&#59; nivel de conciencia aceptable&#59; pH 7&#44;32-7&#44;42&#59; reflejo de tos presente&#59; no incremento de las necesidades de ventilaci&#243;n mec&#225;nica en las &#250;ltimas 24 h&#44; y no intervenci&#243;n con sedaci&#243;n prevista en las pr&#243;ximas 12 h&#46;</p><p class="elsevierStylePara">De los 313 pacientes&#44; 131 &#40;42&#37;&#41; superaron dicho test y fueron extubados con un porcentaje de &#233;xito del 84&#37; &#40;13&#37; precisaron reintubaci&#243;n y 3&#37; ventilaci&#243;n no invasiva&#41;&#46;</p><p class="elsevierStylePara">Los 182 ni&#241;os que no superaron el test de extubaci&#243;n fueron aleatorizados para realizar el destete en 3 grupos &#40;no protocolo&#44; presi&#243;n soporte y volumen soporte&#41; estos grupos fueron similares en cuanto a edad&#44; sexo&#44; tiempo de ventilaci&#243;n previo y diagn&#243;sticos al ingreso&#46; El 66&#37; de los pacientes complet&#243; el estudio&#46;</p><p class="elsevierStylePara">Los datos evaluados en los 3 grupos fueron&#58; tiempo de destete del respirador y &#233;xito o fracaso de la extubaci&#243;n&#46; La duraci&#243;n del proceso de retirada del respirador fue breve&#44; y fueron extubados m&#225;s de la mitad de los ni&#241;os en las primeras 48 h&#46; No se encontraron diferencias significativas en la duraci&#243;n del destete ni en el &#233;xito de la extubaci&#243;n entre los pacientes que fueron sometidos a protocolo y aquellos en que se realizaba de forma estandarizada&#46; Tampoco hubo diferencias entre los pacientes que realizaban el destete en presi&#243;n soporte o en volumen soporte&#46;</p><p class="elsevierStylePara">Los autores encontraron relaci&#243;n entre la cantidad de sedaci&#243;n recibida en las primeras horas del destete y la duraci&#243;n del mismo &#40;p &#60; 0&#44;001&#41; as&#237; como en caso de fracaso de la extubaci&#243;n &#40;p &#60; 0&#44;03&#41;&#44; el proceso era m&#225;s largo y con mayor porcentaje de reintubaci&#243;n cuanto mayor era la sedaci&#243;n recibida&#46; Otro dato encontrado fue la relaci&#243;n significativa entre el sexo y el fracaso en la extubaci&#243;n&#44; los ni&#241;os presentaron un porcentaje mayor de fracaso que las ni&#241;as &#40;p &#60; 0&#44;001&#41;&#46;</p><p class="elsevierStylePara">Los resultados de este estudio contradicen los hallazgos de otros estudios realizados&#44; tanto en adultos<span class="elsevierStyleSup">1&#44;2</span> como en ni&#241;os<span class="elsevierStyleSup">4</span>&#44; que encuentran que el seguimiento de protocolos y gu&#237;as para la extubaci&#243;n producen una disminuci&#243;n del tiempo de ventilaci&#243;n mec&#225;nica y un incremento del &#233;xito de la extubaci&#243;n&#46;</p><p class="elsevierStylePara"> Analizando el estudio de Randolph et al<span class="elsevierStyleSup">3</span>&#44; se observa que los pacientes incluidos son un porcentaje peque&#241;o de los pacientes ventilados&#44; se excluy&#243; a las pacientes m&#225;s dif&#237;ciles por presentar alteraciones cr&#243;nicas de la funci&#243;n respiratoria u otras patolog&#237;as previas que la pudieran afectar&#46; El valor medio del PRIMS &#40;alrededor de 10&#41; y el tiempo medio para el destete &#40;48 h&#41; indican que los ni&#241;os incluidos en el estudio no eran pacientes muy graves&#46; Por otra parte&#44; los pacientes no fueron estratificados por diagn&#243;sticos ni por duraci&#243;n de la ventilaci&#243;n&#44; lo cual puede ser causa de que diferencias importantes en pacientes con patolog&#237;a respiratoria grave puedan ser diluidas al estudiarse conjuntamente con otras patolog&#237;as o con pacientes menos graves&#44; que en general requieren menos tiempo de ventilaci&#243;n mec&#225;nica&#46;</p><p class="elsevierStylePara"> Schultz et al<span class="elsevierStyleSup">4</span>&#44; en un estudio con ni&#241;os&#44; compararon la realizaci&#243;n del destete del respirador seg&#250;n protocolo o seg&#250;n la pr&#225;ctica cl&#237;nica habitual&#44; y objetivaron menor tiempo de destete en el grupo que sigui&#243; el protocolo&#46; Adem&#225;s&#44; como es l&#243;gico&#44; observaron diferencias significativas en el tiempo de destete entre los ni&#241;os sometidos a ventilaci&#243;n mec&#225;nica por causa respiratoria y no respiratoria&#46; Aunque los m&#233;todos de destete y la selecci&#243;n de pacientes fueron diferentes en ambos estudios&#44; los resultados de Randolph et al<span class="elsevierStyleSup">3</span> podr&#237;an haber sido diferentes si se hubieran estratificado los pacientes por grupos de diagn&#243;stico o duraci&#243;n previa de la ventilaci&#243;n mec&#225;nica&#44; dado que los ni&#241;os menos graves o con menor duraci&#243;n de la ventilaci&#243;n mec&#225;nica pueden no necesitar un protocolo para la desconexi&#243;n del respirador&#46;</p><p class="elsevierStylePara">Un dato interesante del estudio de Randolph et al<span class="elsevierStyleSup">3</span>&#44; es la confirmaci&#243;n de que muchos pacientes pedi&#225;tricos no necesitan un destete gradual&#44; sino que pueden ser extubados con &#233;xito despu&#233;s de un test r&#225;pido de extubaci&#243;n&#46; Dicho test puede consistir en mantener una presi&#243;n soporte m&#237;nima para vencer la resistencia del tubo&#44; como en el estudio mencionado&#44; o bien mediante la conexi&#243;n a un tubo en T&#46; No se han encontrado diferencias significativas entre estos 2 m&#233;todos en el logro de una extubaci&#243;n exitosa<span class="elsevierStyleSup">8</span>&#46;</p><p class="elsevierStylePara"> Aunque hay variaciones en los diferentes estudios&#44; en general se considera que un ni&#241;o puede iniciar el destete del respirador cuando cumple los siguientes criterios<span class="elsevierStyleSup">3&#44;4&#44;6&#44;8&#44;9</span>&#58;</p><p class="elsevierStylePara"> &#173; Resoluci&#243;n o mejor&#237;a de la causa de fallo respiratorio&#46;</p><p class="elsevierStylePara"> &#173; Disminuci&#243;n o suspensi&#243;n de la sedaci&#243;n&#46;</p><p class="elsevierStylePara"> &#173; Suspensi&#243;n de los relajantes musculares&#46;</p><p class="elsevierStylePara"> &#173; Nivel de conciencia adecuado&#46;</p><p class="elsevierStylePara"> &#173; Esfuerzo respiratorio espont&#225;neo&#46;</p><p class="elsevierStylePara"> &#173; Reflejo de tos presente&#46;</p><p class="elsevierStylePara"> &#173; Estado hemodin&#225;mico estable&#46;</p><p class="elsevierStylePara"> &#173; Ausencia de signos cl&#237;nicos de sepsis&#46;</p><p class="elsevierStylePara"> &#173; Correcci&#243;n de desequilibrios metab&#243;licos y electrol&#237;ticos importantes&#46;</p><p class="elsevierStylePara"> &#173; Capacidad de oxigenaci&#243;n adecuada con PEEP &#8804; 6-7 cmH<span class="elsevierStyleInf">2</span>O y FiO<span class="elsevierStyleInf">2</span> &#8804; 0&#44;4-0&#44;5&#46;</p><p class="elsevierStylePara">El trabajo de Randolph et al<span class="elsevierStyleSup">3</span>&#44; que recoge datos de 10 unidades de cuidados intensivos pedi&#225;tricos&#44; permite conocer los modos de destete m&#225;s utilizados en ni&#241;os&#46; La ventilaci&#243;n mandatoria intermitente sincronizada &#40;SIMV&#41; combinada con presi&#243;n soporte es la forma m&#225;s utilizada&#44; aunque el uso de presi&#243;n soporte como modo &#250;nico de ventilaci&#243;n va adquiriendo cada vez m&#225;s importancia&#44; y no existe hasta el momento evidencia de que un m&#233;todo sea mejor que otro&#46; En adultos&#44; la presi&#243;n soporte o la utilizaci&#243;n de conexiones diarias a tubo en T parecen ser superiores a la SIMV<span class="elsevierStyleSup">7</span>&#46; Sin embargo&#44; la diversidad en la aplicaci&#243;n de las distintas t&#233;cnicas ha llevado a algunos autores a la conclusi&#243;n&#44; despu&#233;s de la revisi&#243;n de la literatura&#44; de que el modo c&#243;mo se aplica la t&#233;cnica tiene mayor importancia sobre la duraci&#243;n y efecto del destete que la propia t&#233;cnica en s&#237; misma<span class="elsevierStyleSup">10&#44;11</span>&#46; El art&#237;culo de Randolph et al<span class="elsevierStyleSup">3</span> es el primero que compara 2 protocolos de destete en ni&#241;os &#40;presi&#243;n soporte&#47;volumen soporte&#41; sin encontrar diferencias significativas&#46; Sin embargo&#44; ser&#237;a necesario realizar estudios controlados multic&#233;ntricos en ni&#241;os con protocolos de destete bien definidos para valorar cu&#225;l es el mejor m&#233;todo para la desconexi&#243;n del respirador&#46;</p><p class="elsevierStylePara">Por otra parte&#44; el establecimiento de protocolos debe tener en cuenta la variabilidad en los diagn&#243;sticos&#44; la enfermedad subyacente y las necesidades de sedaci&#243;n tan importantes que en ocasiones precisa el paciente pedi&#225;trico&#46; Aunque el objetivo es realizar la retirada del respirador en el menor tiempo posible&#44; no debe olvidarse el bienestar del paciente&#46;</p><p class="elsevierStylePara"> Randolph et al<span class="elsevierStyleSup">3</span> encuentran una incidencia de fracaso de la extubaci&#243;n similar a la referida en la literatura &#40;alrededor del 16&#37;&#41;&#44; sin encontrar diferencias en relaci&#243;n al m&#233;todo con que se realice el destete&#46;</p><p class="elsevierStylePara">El fracaso del destete puede ser bien por incapacidad para alcanzar la respiraci&#243;n espont&#225;nea impidiendo la extubaci&#243;n o bien por fracaso de la extubaci&#243;n &#40;necesidad de reintubaci&#243;n o ventilaci&#243;n no invasiva en las siguientes 48 h&#41;&#46;</p><p class="elsevierStylePara">En el estudio comentado<span class="elsevierStyleSup">3</span>&#44; el fracaso del destete fue debido fundamentalmente al fracaso de la extubaci&#243;n&#46; Dos variables&#44; una de ellas esperada &#40;nivel de sedaci&#243;n en las primeras 24 h del destete&#41; y otra de causa no clara &#40;sexo masculino&#41; se relacionaron con el fracaso de la extubaci&#243;n&#46;</p><p class="elsevierStylePara">Es importante establecer criterios de extubaci&#243;n en relaci&#243;n a variables que pueden predecir su &#233;xito o fracaso&#44; y as&#237; evitar la prolongaci&#243;n innecesaria de la ventilaci&#243;n mec&#225;nica en aquellos pacientes con bajo riesgo de fracaso&#44; sin incurrir en la extubaci&#243;n prematura en aquellos pacientes con mayor riesgo&#46;</p><p class="elsevierStylePara">La extubaci&#243;n se lleva a cabo cuando el paciente&#44; adem&#225;s de tener un nivel de conciencia adecuado y reflejo de tos presente&#44; es capaz de mantener un nivel de oxigenaci&#243;n aceptable con un m&#237;nimo valor de PEEP&#44; FiO<span class="elsevierStyleInf">2</span> y presi&#243;n soporte&#44; un volumen tidal espont&#225;neo adecuado &#40;alrededor 5 ml&#47;kg&#41; y una frecuencia respiratoria acorde con su edad&#44; lo que refleja que el esfuerzo realizado por el paciente es adecuado&#46; Los &#237;ndices predictivos del &#233;xito de la extubaci&#243;n valorados en los adultos &#40;frecuencia respiratoria&#47;volumen tidal espont&#225;neo o el &#237;ndice CROP&#41; no se han establecido en ni&#241;os&#44; puesto que la frecuencia y el volumen tidal var&#237;an en relaci&#243;n a la edad y el peso<span class="elsevierStyleSup">12-14</span>&#46; Venkataraman et al<span class="elsevierStyleSup">12</span> encontraron que el an&#225;lisis de determinadas variables preextubaci&#243;n&#44; permite predecir el riesgo de reintubaci&#243;n&#46; Estas variables son&#58; el volumen tidal espont&#225;neo &#40;V<span class="elsevierStyleInf">t</span>&#41; que refleja el esfuerzo inspiratorio&#44; el pico de presi&#243;n y la elasticidad din&#225;mica que valoran la sobrecarga respiratoria y el cociente V<span class="elsevierStyleInf">t</span>&#47;Ti &#40;Ti&#58; tiempo inspiratorio&#41;&#46; Adem&#225;s&#44; un nivel de soporte elevado preextubaci&#243;n se asocia tambi&#233;n con fracaso de la extubaci&#243;n<span class="elsevierStyleSup">13</span>&#46; Sin embargo&#44; Farias et al<span class="elsevierStyleSup">6</span> encuentran que aunque par&#225;metros como el V<span class="elsevierStyleInf">t</span> o el &#237;ndice f&#47;V<span class="elsevierStyleInf">t</span> &#40;f&#58; frecuencia&#41; permiten identificar a ni&#241;os con alta probabilidad de extubaci&#243;n exitosa&#44; fallan en la predicci&#243;n del fracaso de la extubaci&#243;n y&#44; por tanto&#44; no deben sustituir a la evaluaci&#243;n cl&#237;nica&#46;</p><p class="elsevierStylePara"> Como conclusiones&#44; resaltamos que la mayor&#237;a de los ni&#241;os sometidos a ventilaci&#243;n mec&#225;nica no necesitan un proceso de destete prolongado&#46; Todos aquellos ni&#241;os que hayan superado el proceso que les ha llevado a la ventilaci&#243;n mec&#225;nica o est&#233;n en v&#237;as de superarlo&#44; deben ser frecuentemente evaluados para determinar su capacidad de respiraci&#243;n espont&#225;nea y extubaci&#243;n&#46; Son necesarios nuevos estudios que comparen m&#233;todos y protocolos de destete en los pacientes m&#225;s complejos&#44; ya que probablemente ser&#225; en &#233;stos en quienes se encuentren diferencias seg&#250;n los m&#233;todos empleados&#46; El nivel de sedaci&#243;n es un determinante importante tanto en la duraci&#243;n del destete como en el &#233;xito o fracaso de la extubaci&#243;n&#44; por lo que es importante encontrar el equilibrio entre el bienestar del paciente y la no interferencia con el proceso de retirada del respirador&#46;</p>"
    "pdfFichero" => "64v27n10a13055982pdf001.pdf"
    "tienePdf" => true
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:1 [
          "bibliografiaReferencia" => array:14 [
            0 => array:3 [
              "identificador" => "bib1"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Jhon RE&#44; Prentice D&#44; Sauer S&#44; et al&#46; A randomized&#44; controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "Kollef HK"
                            1 => "Shapiro SD"
                            2 => "Silver P"
                            3 => "St&#46;J&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "1997"
                        "volumen" => "25"
                        "paginaInicial" => "567"
                        "paginaFinal" => "74"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9142019"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib2"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Effects of multifaceted&#44; multidisciplinary&#44; hospital-wide quality improvement program on weaning from mechanical ventilation&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "Smyrnios NA"
                            1 => "Connolly A"
                            2 => "Wilson MM"
                            3 => "Curley FJ"
                            4 => "French CT"
                            5 => "Heard SO"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2002"
                        "volumen" => "30"
                        "paginaInicial" => "1224"
                        "paginaFinal" => "30"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12072672"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib3"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Effect of mechanical ventilation weaning protocols on respiratory outcomes in infants and children&#46; A randomized controlled trial&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "Randolph G"
                            1 => "Wypij D"
                            2 => "Venkataraman ST"
                            3 => "Hanson JH"
                            4 => "Gedeit RG"
                            5 => "Meert KL"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "JAMA"
                        "fecha" => "2002"
                        "volumen" => "288"
                        "paginaInicial" => "2561"
                        "paginaFinal" => "8"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12444863"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib4"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Weaning children for mechanical ventilation&#46; A prospective randomized trial of protocol-directed versus physian-directed weaning&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "Schultz TR"
                            1 => "Lin RJ"
                            2 => "Watzman HM"
                            3 => "Durning SM"
                            4 => "Hales R"
                            5 => "Woodson A"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Respir Care"
                        "fecha" => "2001"
                        "volumen" => "46"
                        "paginaInicial" => "772"
                        "paginaFinal" => "82"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11463367"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib5"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Compared with specialist registrars&#44; experienced staff nurses shorten the duration of weaning neonates from mechanical ventilation&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "Luyt K"
                            1 => "Boyle B"
                            2 => "Wright DE"
                            3 => "Petros AJ&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1097/01.PCC.0000031366.07233.91"
                      "Revista" => array:6 [
                        "tituloSerie" => "Pediatr Crit Care Med"
                        "fecha" => "2002"
                        "volumen" => "3"
                        "paginaInicial" => "351"
                        "paginaFinal" => "4"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12780953"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib6"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Weaning from mechanical ventilation in pediatric intensive care patients&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "Farias JA"
                            1 => "Alia I"
                            2 => "Esteban A"
                            3 => "Golubicki AN"
                            4 => "Olazarri FA&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Intensive Care Med"
                        "fecha" => "1998"
                        "volumen" => "24"
                        "paginaInicial" => "1070"
                        "paginaFinal" => "5"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/9840242"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib7"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "A comparison of four methods of weaning patients from mechanical ventilation&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "Esteban A"
                            1 => "Frutos F"
                            2 => "Tobin MJ"
                            3 => "Alia I"
                            4 => "Solsona JF"
                            5 => "Valverd&#250; I"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1056/NEJM199502093320601"
                      "Revista" => array:6 [
                        "tituloSerie" => "N Engl J Med"
                        "fecha" => "1995"
                        "volumen" => "332"
                        "paginaInicial" => "345"
                        "paginaFinal" => "50"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/7823995"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib8"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "A comparison of two methods to perform a breathing trial before extubation in pediatric intensive care patients&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "Farias JA"
                            1 => "Retta A"
                            2 => "Alia I"
                            3 => "Olazarri FA"
                            4 => "Esteban A"
                            5 => "Golubicki A"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s001340101035"
                      "Revista" => array:6 [
                        "tituloSerie" => "Intensive Care Med"
                        "fecha" => "2001"
                        "volumen" => "27"
                        "paginaInicial" => "1649"
                        "paginaFinal" => "54"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11685307"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib9"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Evidence-based guidelines for weaning and discontinuing ventilatory support&#46; A collective Task Force facilitated by the American College of Chest Physicians&#59; the American Association for Respirattory Care&#44; and the American College of Critical Care Medicine&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:7 [
                            0 => "MacIntyre NR"
                            1 => "Cook DJ"
                            2 => "Epsteien SK"
                            3 => "Fink JB"
                            4 => "Heffner JE"
                            5 => "Hess D"
                            6 => "et al&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Chest"
                        "fecha" => "2001"
                        "volumen" => "120"
                        "paginaInicial" => "375S"
                        "paginaFinal" => "95S"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11742959"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib10"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Is there a preferred technique for weaning the difficult-to-wean patient&#63; A systematic review of the literature&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "Butler R"
                            1 => "Keenan SP"
                            2 => "Inman KJ"
                            3 => "Sibbald WJ"
                            4 => "Block G&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "1999"
                        "volumen" => "27"
                        "paginaInicial" => "2331"
                        "paginaFinal" => "6"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10579244"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            10 => array:3 [
              "identificador" => "bib11"
              "etiqueta" => "11"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Introduction to a series of systematic reviews of weaning from mechanical ventilation&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:6 [
                            0 => "Meade M"
                            1 => "Guyatt G"
                            2 => "Griffith L"
                            3 => "Booker L"
                            4 => "Randall J"
                            5 => "Cook DJ&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Chest"
                        "fecha" => "2001"
                        "volumen" => "120"
                        "paginaInicial" => "396S"
                        "paginaFinal" => "9S"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/11742960"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            11 => array:3 [
              "identificador" => "bib12"
              "etiqueta" => "12"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Validation of predictors of extubation sucess an failure in mechanically ventilated infants and children&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "Venkataraman ST"
                            1 => "Khan N"
                            2 => "Brown A&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "2000"
                        "volumen" => "28"
                        "paginaInicial" => "2991"
                        "paginaFinal" => "6"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/10966284"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            12 => array:3 [
              "identificador" => "bib13"
              "etiqueta" => "13"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Predictors of extubation sucess an failure in mechanically ventilated infants and children&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "Khan N"
                            1 => "Brown A"
                            2 => "Venkataraman ST&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Crit Care Med"
                        "fecha" => "1996"
                        "volumen" => "24"
                        "paginaInicial" => "1568"
                        "paginaFinal" => "79"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/8797633"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            13 => array:3 [
              "identificador" => "bib14"
              "etiqueta" => "14"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:3 [
                      "titulo" => "Comparison of predictors of extubation from mechanical ventilation in children&#46;"
                      "idioma" => "en"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:3 [
                            0 => "Mannzur TI"
                            1 => "Greenough A"
                            2 => "Rafferty GF&#46;"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Pediatr Crit Care Med"
                        "fecha" => "2000"
                        "volumen" => "1"
                        "paginaInicial" => "28"
                        "paginaFinal" => "32"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/12813282"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/02105691/0000002700000010/v0_201212111616/13055982/v0_201212111617/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "437"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Punto de vista"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02105691/0000002700000010/v0_201212111616/13055982/v0_201212111617/es/64v27n10a13055982pdf001.pdf?idApp=WMIE&text.app=https://medintensiva.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/13055982?idApp=WMIE"
]
Compartir
Información de la revista
Vol. 27. Núm. 10.
Páginas 673-675 (diciembre 2003)
Compartir
Compartir
Descargar PDF
Más opciones de artículo
Vol. 27. Núm. 10.
Páginas 673-675 (diciembre 2003)
Acceso a texto completo
Ventilación mecánica en pediatría. ¿Cómo y cuándo extubar?
Mechanical ventilation in pediatrics. How and when to extubate?
Visitas
29799
A. Martínez de Azagraa, J. Casado Floresa, R. Jiménez Garcíaa
a Servicio de Cuidados Intensivos. Hospital Universitario Niño Jesús. Universidad Autónoma de Madrid. Madrid. España.
Este artículo ha recibido
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Texto completo

La ventilación mecánica es una técnica absolutamente necesaria en el soporte vital de muchos niños; sin embargo implica importantes riesgos y complicaciones. El destete del respirador o weaning es el proceso de retirada de la ventilación mecánica y es, por tanto, un período de transición entre la respiración artificial y la espontánea.

El objetivo del destete es ayudar al paciente a recuperar la respiración espontánea en el menor tiempo posible y prevenir así las complicaciones de una ventilación mecánica prolongada sin incurrir en un riesgo demasiado alto de reintubación.

Las preguntas clave ante el niño con ventilación mecánica son: 1) cómo y cuándo iniciar el destete, y 2) cuáles son los predictores de éxito o fracaso de la desconexión del respirador.

Mientras que en adultos existen numerosos estudios1,2 que avalan el seguimiento de protocolos específicos para realizar el destete del respirador, en pediatría existen pocos trabajos3-5 que valoren el modo de realizarlo, y los que existen llegan conclusiones diferentes.

Randolph et al3, en un trabajo denominado Effect of mechanical ventilation weaning protocols on

respiratory outcomes in infants and children,
comparan la realización del destete según protocolo con el destete basado en la experiencia clínica. Los objetivos fundamentales de este estudio fueron: 1) evaluar si el seguimiento de un protocolo de destete obtenía mejores resultados que el realizado de forma estandarizada, y 2) si un determinado protocolo (volumen soporte) era mejor que otro (presión soporte) para alcanzar el objetivo de la extubación. Como objetivos secundarios se plantearon evaluar la aplicación de criterios de predicción de éxito o fracaso de la extubación y estudiar la influencia de la sedación recibida durante el procedimiento sobre los resultados.

Se trata de un estudio prospectivo multicéntrico en el que los autores incluyeron a aquellos niños (desde recién nacidos con edad gestacional > 38 semanas hasta 18 años) que precisaron ventilación mecánica durante más de 24 h. Los autores excluyeron todos los pacientes que presentaron alteraciones congénitas o adquiridas de la vía aérea superior, hernia o parálisis diafragmática, hipertensión pulmonar, pacientes que precisaban respirador o ventilación no invasiva en su situación basal, capacidad pulmonar disminuida, cardiopatía congénita cianótica, trasplante de médula ósea, traumatismo espinal o patología neuromuscular. Fueron excluidos 1.597 pacientes de un total de 2.349. De los 752 pacientes restantes, 439 no fueron incluidos por falta de consentimiento, traslado a otros hospitales, no disponibilidad de equipo u otros motivos, y fueron definitivamente incluidos en el estudio 313 pacientes (12,8% de los pacientes ventilados).

Los autores consideraron, de acuerdo a la experiencia previa6,7, que muchos de los niños no requerían un descenso progresivo de la asistencia y podían ser extubados directamente. A éstos se les sometió a un test de extubación basado en presión soporte.

Los criterios para realizar el test de extubación fueron los siguientes: FiO2 ≤ 0,6; presión positiva espiratoria final (PEEP) ≤ 7 cmH2O; esfuerzo respiratorio espontáneo; nivel de conciencia aceptable; pH 7,32-7,42; reflejo de tos presente; no incremento de las necesidades de ventilación mecánica en las últimas 24 h, y no intervención con sedación prevista en las próximas 12 h.

De los 313 pacientes, 131 (42%) superaron dicho test y fueron extubados con un porcentaje de éxito del 84% (13% precisaron reintubación y 3% ventilación no invasiva).

Los 182 niños que no superaron el test de extubación fueron aleatorizados para realizar el destete en 3 grupos (no protocolo, presión soporte y volumen soporte) estos grupos fueron similares en cuanto a edad, sexo, tiempo de ventilación previo y diagnósticos al ingreso. El 66% de los pacientes completó el estudio.

Los datos evaluados en los 3 grupos fueron: tiempo de destete del respirador y éxito o fracaso de la extubación. La duración del proceso de retirada del respirador fue breve, y fueron extubados más de la mitad de los niños en las primeras 48 h. No se encontraron diferencias significativas en la duración del destete ni en el éxito de la extubación entre los pacientes que fueron sometidos a protocolo y aquellos en que se realizaba de forma estandarizada. Tampoco hubo diferencias entre los pacientes que realizaban el destete en presión soporte o en volumen soporte.

Los autores encontraron relación entre la cantidad de sedación recibida en las primeras horas del destete y la duración del mismo (p < 0,001) así como en caso de fracaso de la extubación (p < 0,03), el proceso era más largo y con mayor porcentaje de reintubación cuanto mayor era la sedación recibida. Otro dato encontrado fue la relación significativa entre el sexo y el fracaso en la extubación, los niños presentaron un porcentaje mayor de fracaso que las niñas (p < 0,001).

Los resultados de este estudio contradicen los hallazgos de otros estudios realizados, tanto en adultos1,2 como en niños4, que encuentran que el seguimiento de protocolos y guías para la extubación producen una disminución del tiempo de ventilación mecánica y un incremento del éxito de la extubación.

Analizando el estudio de Randolph et al3, se observa que los pacientes incluidos son un porcentaje pequeño de los pacientes ventilados, se excluyó a las pacientes más difíciles por presentar alteraciones crónicas de la función respiratoria u otras patologías previas que la pudieran afectar. El valor medio del PRIMS (alrededor de 10) y el tiempo medio para el destete (48 h) indican que los niños incluidos en el estudio no eran pacientes muy graves. Por otra parte, los pacientes no fueron estratificados por diagnósticos ni por duración de la ventilación, lo cual puede ser causa de que diferencias importantes en pacientes con patología respiratoria grave puedan ser diluidas al estudiarse conjuntamente con otras patologías o con pacientes menos graves, que en general requieren menos tiempo de ventilación mecánica.

Schultz et al4, en un estudio con niños, compararon la realización del destete del respirador según protocolo o según la práctica clínica habitual, y objetivaron menor tiempo de destete en el grupo que siguió el protocolo. Además, como es lógico, observaron diferencias significativas en el tiempo de destete entre los niños sometidos a ventilación mecánica por causa respiratoria y no respiratoria. Aunque los métodos de destete y la selección de pacientes fueron diferentes en ambos estudios, los resultados de Randolph et al3 podrían haber sido diferentes si se hubieran estratificado los pacientes por grupos de diagnóstico o duración previa de la ventilación mecánica, dado que los niños menos graves o con menor duración de la ventilación mecánica pueden no necesitar un protocolo para la desconexión del respirador.

Un dato interesante del estudio de Randolph et al3, es la confirmación de que muchos pacientes pediátricos no necesitan un destete gradual, sino que pueden ser extubados con éxito después de un test rápido de extubación. Dicho test puede consistir en mantener una presión soporte mínima para vencer la resistencia del tubo, como en el estudio mencionado, o bien mediante la conexión a un tubo en T. No se han encontrado diferencias significativas entre estos 2 métodos en el logro de una extubación exitosa8.

Aunque hay variaciones en los diferentes estudios, en general se considera que un niño puede iniciar el destete del respirador cuando cumple los siguientes criterios3,4,6,8,9:

­ Resolución o mejoría de la causa de fallo respiratorio.

­ Disminución o suspensión de la sedación.

­ Suspensión de los relajantes musculares.

­ Nivel de conciencia adecuado.

­ Esfuerzo respiratorio espontáneo.

­ Reflejo de tos presente.

­ Estado hemodinámico estable.

­ Ausencia de signos clínicos de sepsis.

­ Corrección de desequilibrios metabólicos y electrolíticos importantes.

­ Capacidad de oxigenación adecuada con PEEP ≤ 6-7 cmH2O y FiO2 ≤ 0,4-0,5.

El trabajo de Randolph et al3, que recoge datos de 10 unidades de cuidados intensivos pediátricos, permite conocer los modos de destete más utilizados en niños. La ventilación mandatoria intermitente sincronizada (SIMV) combinada con presión soporte es la forma más utilizada, aunque el uso de presión soporte como modo único de ventilación va adquiriendo cada vez más importancia, y no existe hasta el momento evidencia de que un método sea mejor que otro. En adultos, la presión soporte o la utilización de conexiones diarias a tubo en T parecen ser superiores a la SIMV7. Sin embargo, la diversidad en la aplicación de las distintas técnicas ha llevado a algunos autores a la conclusión, después de la revisión de la literatura, de que el modo cómo se aplica la técnica tiene mayor importancia sobre la duración y efecto del destete que la propia técnica en sí misma10,11. El artículo de Randolph et al3 es el primero que compara 2 protocolos de destete en niños (presión soporte/volumen soporte) sin encontrar diferencias significativas. Sin embargo, sería necesario realizar estudios controlados multicéntricos en niños con protocolos de destete bien definidos para valorar cuál es el mejor método para la desconexión del respirador.

Por otra parte, el establecimiento de protocolos debe tener en cuenta la variabilidad en los diagnósticos, la enfermedad subyacente y las necesidades de sedación tan importantes que en ocasiones precisa el paciente pediátrico. Aunque el objetivo es realizar la retirada del respirador en el menor tiempo posible, no debe olvidarse el bienestar del paciente.

Randolph et al3 encuentran una incidencia de fracaso de la extubación similar a la referida en la literatura (alrededor del 16%), sin encontrar diferencias en relación al método con que se realice el destete.

El fracaso del destete puede ser bien por incapacidad para alcanzar la respiración espontánea impidiendo la extubación o bien por fracaso de la extubación (necesidad de reintubación o ventilación no invasiva en las siguientes 48 h).

En el estudio comentado3, el fracaso del destete fue debido fundamentalmente al fracaso de la extubación. Dos variables, una de ellas esperada (nivel de sedación en las primeras 24 h del destete) y otra de causa no clara (sexo masculino) se relacionaron con el fracaso de la extubación.

Es importante establecer criterios de extubación en relación a variables que pueden predecir su éxito o fracaso, y así evitar la prolongación innecesaria de la ventilación mecánica en aquellos pacientes con bajo riesgo de fracaso, sin incurrir en la extubación prematura en aquellos pacientes con mayor riesgo.

La extubación se lleva a cabo cuando el paciente, además de tener un nivel de conciencia adecuado y reflejo de tos presente, es capaz de mantener un nivel de oxigenación aceptable con un mínimo valor de PEEP, FiO2 y presión soporte, un volumen tidal espontáneo adecuado (alrededor 5 ml/kg) y una frecuencia respiratoria acorde con su edad, lo que refleja que el esfuerzo realizado por el paciente es adecuado. Los índices predictivos del éxito de la extubación valorados en los adultos (frecuencia respiratoria/volumen tidal espontáneo o el índice CROP) no se han establecido en niños, puesto que la frecuencia y el volumen tidal varían en relación a la edad y el peso12-14. Venkataraman et al12 encontraron que el análisis de determinadas variables preextubación, permite predecir el riesgo de reintubación. Estas variables son: el volumen tidal espontáneo (Vt) que refleja el esfuerzo inspiratorio, el pico de presión y la elasticidad dinámica que valoran la sobrecarga respiratoria y el cociente Vt/Ti (Ti: tiempo inspiratorio). Además, un nivel de soporte elevado preextubación se asocia también con fracaso de la extubación13. Sin embargo, Farias et al6 encuentran que aunque parámetros como el Vt o el índice f/Vt (f: frecuencia) permiten identificar a niños con alta probabilidad de extubación exitosa, fallan en la predicción del fracaso de la extubación y, por tanto, no deben sustituir a la evaluación clínica.

Como conclusiones, resaltamos que la mayoría de los niños sometidos a ventilación mecánica no necesitan un proceso de destete prolongado. Todos aquellos niños que hayan superado el proceso que les ha llevado a la ventilación mecánica o estén en vías de superarlo, deben ser frecuentemente evaluados para determinar su capacidad de respiración espontánea y extubación. Son necesarios nuevos estudios que comparen métodos y protocolos de destete en los pacientes más complejos, ya que probablemente será en éstos en quienes se encuentren diferencias según los métodos empleados. El nivel de sedación es un determinante importante tanto en la duración del destete como en el éxito o fracaso de la extubación, por lo que es importante encontrar el equilibrio entre el bienestar del paciente y la no interferencia con el proceso de retirada del respirador.

Bibliografía
[1]
Kollef HK, Shapiro SD, Silver P, St.J..
Jhon RE, Prentice D, Sauer S, et al. A randomized, controlled trial of protocol-directed versus physician-directed weaning from mechanical ventilation..
Crit Care Med, 25 (1997), pp. 567-74
[2]
Smyrnios NA, Connolly A, Wilson MM, Curley FJ, French CT, Heard SO, et al..
Effects of multifaceted, multidisciplinary, hospital-wide quality improvement program on weaning from mechanical ventilation..
Crit Care Med, 30 (2002), pp. 1224-30
[3]
Randolph G, Wypij D, Venkataraman ST, Hanson JH, Gedeit RG, Meert KL, et al..
Effect of mechanical ventilation weaning protocols on respiratory outcomes in infants and children. A randomized controlled trial..
JAMA, 288 (2002), pp. 2561-8
[4]
Schultz TR, Lin RJ, Watzman HM, Durning SM, Hales R, Woodson A, et al..
Weaning children for mechanical ventilation. A prospective randomized trial of protocol-directed versus physian-directed weaning..
Respir Care, 46 (2001), pp. 772-82
[5]
Luyt K, Boyle B, Wright DE, Petros AJ..
Compared with specialist registrars, experienced staff nurses shorten the duration of weaning neonates from mechanical ventilation..
Pediatr Crit Care Med, 3 (2002), pp. 351-4
[6]
Farias JA, Alia I, Esteban A, Golubicki AN, Olazarri FA..
Weaning from mechanical ventilation in pediatric intensive care patients..
Intensive Care Med, 24 (1998), pp. 1070-5
[7]
Esteban A, Frutos F, Tobin MJ, Alia I, Solsona JF, Valverdú I, et al..
A comparison of four methods of weaning patients from mechanical ventilation..
N Engl J Med, 332 (1995), pp. 345-50
[8]
Farias JA, Retta A, Alia I, Olazarri FA, Esteban A, Golubicki A, et al..
A comparison of two methods to perform a breathing trial before extubation in pediatric intensive care patients..
Intensive Care Med, 27 (2001), pp. 1649-54
[9]
MacIntyre NR, Cook DJ, Epsteien SK, Fink JB, Heffner JE, Hess D, et al..
Evidence-based guidelines for weaning and discontinuing ventilatory support. A collective Task Force facilitated by the American College of Chest Physicians; the American Association for Respirattory Care, and the American College of Critical Care Medicine..
Chest, 120 (2001), pp. 375S-95S
[10]
Butler R, Keenan SP, Inman KJ, Sibbald WJ, Block G..
Is there a preferred technique for weaning the difficult-to-wean patient? A systematic review of the literature..
Crit Care Med, 27 (1999), pp. 2331-6
[11]
Meade M, Guyatt G, Griffith L, Booker L, Randall J, Cook DJ..
Introduction to a series of systematic reviews of weaning from mechanical ventilation..
Chest, 120 (2001), pp. 396S-9S
[12]
Venkataraman ST, Khan N, Brown A..
Validation of predictors of extubation sucess an failure in mechanically ventilated infants and children..
Crit Care Med, 28 (2000), pp. 2991-6
[13]
Khan N, Brown A, Venkataraman ST..
Predictors of extubation sucess an failure in mechanically ventilated infants and children..
Crit Care Med, 24 (1996), pp. 1568-79
[14]
Mannzur TI, Greenough A, Rafferty GF..
Comparison of predictors of extubation from mechanical ventilation in children..
Pediatr Crit Care Med, 1 (2000), pp. 28-32
Descargar PDF
Idiomas
Medicina Intensiva
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?