array:24 [
  "pii" => "S0210569117302061"
  "issn" => "02105691"
  "doi" => "10.1016/j.medin.2017.06.009"
  "estado" => "S300"
  "fechaPublicacion" => "2017-12-01"
  "aid" => "1088"
  "copyright" => "Elsevier España, S.L.U. y SEMICYUC"
  "copyrightAnyo" => "2017"
  "documento" => "simple-article"
  "crossmark" => 1
  "subdocumento" => "crp"
  "cita" => "Med Intensiva. 2017;41:569-70"
  "abierto" => array:3 [
    "ES" => true
    "ES2" => true
    "LATM" => true
  ]
  "gratuito" => true
  "lecturas" => array:2 [
    "total" => 2582
    "formatos" => array:3 [
      "EPUB" => 201
      "HTML" => 1562
      "PDF" => 819
    ]
  ]
  "Traduccion" => array:1 [
    "en" => array:19 [
      "pii" => "S2173572717301911"
      "issn" => "21735727"
      "doi" => "10.1016/j.medine.2017.10.007"
      "estado" => "S300"
      "fechaPublicacion" => "2017-12-01"
      "aid" => "1088"
      "copyright" => "Elsevier España, S.L.U. and SEMICYUC"
      "documento" => "simple-article"
      "crossmark" => 1
      "subdocumento" => "crp"
      "cita" => "Med Intensiva. 2017;41:569-70"
      "abierto" => array:3 [
        "ES" => true
        "ES2" => true
        "LATM" => true
      ]
      "gratuito" => true
      "lecturas" => array:2 [
        "total" => 1440
        "formatos" => array:3 [
          "EPUB" => 172
          "HTML" => 750
          "PDF" => 518
        ]
      ]
      "en" => array:10 [
        "idiomaDefecto" => true
        "cabecera" => "<span class="elsevierStyleTextfn">Scientific Letter</span>"
        "titulo" => "Assessment of the reliability of the accelerometers feedback devices depending on the surface on which cardiopulmonary resuscitation is performed"
        "tienePdf" => "en"
        "tieneTextoCompleto" => "en"
        "paginas" => array:1 [
          0 => array:2 [
            "paginaInicial" => "569"
            "paginaFinal" => "570"
          ]
        ]
        "titulosAlternativos" => array:1 [
          "es" => array:1 [
            "titulo" => "Evaluaci&#243;n de la fiabilidad de los dispositivos aceler&#243;metros de retroalimentaci&#243;n inmediata en funci&#243;n de la superficie en la que se realice la reanimaci&#243;n cardiopulmonar"
          ]
        ]
        "contieneTextoCompleto" => array:1 [
          "en" => true
        ]
        "contienePdf" => array:1 [
          "en" => true
        ]
        "autores" => array:1 [
          0 => array:2 [
            "autoresLista" => "M&#46; Freire Tellado, R&#46; Navarro Pat&#243;n, M&#46;P&#46; Pav&#243;n Prieto, J&#46;D&#46; V&#225;zquez L&#243;pez, J&#46; Mateos Lorenzo, M&#46;A&#46; Neira P&#225;jaro"
            "autores" => array:6 [
              0 => array:2 [
                "nombre" => "M&#46;"
                "apellidos" => "Freire Tellado"
              ]
              1 => array:2 [
                "nombre" => "R&#46;"
                "apellidos" => "Navarro Pat&#243;n"
              ]
              2 => array:2 [
                "nombre" => "M&#46;P&#46;"
                "apellidos" => "Pav&#243;n Prieto"
              ]
              3 => array:2 [
                "nombre" => "J&#46;D&#46;"
                "apellidos" => "V&#225;zquez L&#243;pez"
              ]
              4 => array:2 [
                "nombre" => "J&#46;"
                "apellidos" => "Mateos Lorenzo"
              ]
              5 => array:2 [
                "nombre" => "M&#46;A&#46;"
                "apellidos" => "Neira P&#225;jaro"
              ]
            ]
          ]
        ]
      ]
      "idiomaDefecto" => "en"
      "Traduccion" => array:1 [
        "es" => array:9 [
          "pii" => "S0210569117302061"
          "doi" => "10.1016/j.medin.2017.06.009"
          "estado" => "S300"
          "subdocumento" => ""
          "abierto" => array:3 [
            "ES" => true
            "ES2" => true
            "LATM" => true
          ]
          "gratuito" => true
          "lecturas" => array:1 [
            "total" => 0
          ]
          "idiomaDefecto" => "es"
          "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0210569117302061?idApp=WMIE"
        ]
      ]
      "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173572717301911?idApp=WMIE"
      "url" => "/21735727/0000004100000009/v1_201711250720/S2173572717301911/v1_201711250720/en/main.assets"
    ]
  ]
  "itemSiguiente" => array:19 [
    "pii" => "S0210569116302637"
    "issn" => "02105691"
    "doi" => "10.1016/j.medin.2016.11.009"
    "estado" => "S300"
    "fechaPublicacion" => "2017-12-01"
    "aid" => "1011"
    "copyright" => "Elsevier Espa&#241;a&#44; S&#46;L&#46;U&#46; y SEMICYUC"
    "documento" => "simple-article"
    "crossmark" => 1
    "subdocumento" => "crp"
    "cita" => "Med Intensiva. 2017;41:571-2"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 3299
      "formatos" => array:3 [
        "EPUB" => 156
        "HTML" => 2048
        "PDF" => 1095
      ]
    ]
    "en" => array:10 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Scientific Letter</span>"
      "titulo" => "High-flow nasal cannula oxygen for reverting severe acute exacerbation of chronic obstructive pulmonary disease&#58; A case report"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "571"
          "paginaFinal" => "572"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "es" => array:1 [
          "titulo" => "Oxigenoterapia de alto flujo con c&#225;nula nasal en el tratamiento de la exacerbaci&#243;n de la enfermedad pulmonar obstructiva cr&#243;nica&#58; informe de un caso"
        ]
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "G&#46; Plotnikow, A&#46;W&#46; Thille, D&#46; Vasquez, R&#46; Pratto, P&#46; Desmery"
          "autores" => array:5 [
            0 => array:2 [
              "nombre" => "G&#46;"
              "apellidos" => "Plotnikow"
            ]
            1 => array:2 [
              "nombre" => "A&#46;W&#46;"
              "apellidos" => "Thille"
            ]
            2 => array:2 [
              "nombre" => "D&#46;"
              "apellidos" => "Vasquez"
            ]
            3 => array:2 [
              "nombre" => "R&#46;"
              "apellidos" => "Pratto"
            ]
            4 => array:2 [
              "nombre" => "P&#46;"
              "apellidos" => "Desmery"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2173572717301947"
        "doi" => "10.1016/j.medine.2016.11.011"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173572717301947?idApp=WMIE"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0210569116302637?idApp=WMIE"
    "url" => "/02105691/0000004100000009/v1_201711250711/S0210569116302637/v1_201711250711/en/main.assets"
  ]
  "itemAnterior" => array:19 [
    "pii" => "S0210569117300669"
    "issn" => "02105691"
    "doi" => "10.1016/j.medin.2017.01.012"
    "estado" => "S300"
    "fechaPublicacion" => "2017-12-01"
    "aid" => "1044"
    "copyright" => "Elsevier Espa&#241;a&#44; S&#46;L&#46;U&#46; y SEMICYUC"
    "documento" => "article"
    "crossmark" => 1
    "subdocumento" => "ssu"
    "cita" => "Med Intensiva. 2017;41:559-68"
    "abierto" => array:3 [
      "ES" => true
      "ES2" => true
      "LATM" => true
    ]
    "gratuito" => true
    "lecturas" => array:2 [
      "total" => 7937
      "formatos" => array:3 [
        "EPUB" => 218
        "HTML" => 5557
        "PDF" => 2162
      ]
    ]
    "en" => array:13 [
      "idiomaDefecto" => true
      "cabecera" => "<span class="elsevierStyleTextfn">Review</span>"
      "titulo" => "Organ donor management&#58; Eight common recommendations and actions that deserve reflection"
      "tienePdf" => "en"
      "tieneTextoCompleto" => "en"
      "tieneResumen" => array:2 [
        0 => "en"
        1 => "es"
      ]
      "paginas" => array:1 [
        0 => array:2 [
          "paginaInicial" => "559"
          "paginaFinal" => "568"
        ]
      ]
      "titulosAlternativos" => array:1 [
        "es" => array:1 [
          "titulo" => "Tratamiento del donante de &#243;rganos&#46; Ocho recomendaciones y actuaciones habituales que merecen una reflexi&#243;n"
        ]
      ]
      "contieneResumen" => array:2 [
        "en" => true
        "es" => true
      ]
      "contieneTextoCompleto" => array:1 [
        "en" => true
      ]
      "contienePdf" => array:1 [
        "en" => true
      ]
      "resumenGrafico" => array:2 [
        "original" => 0
        "multimedia" => array:7 [
          "identificador" => "fig0005"
          "etiqueta" => "Figure 1"
          "tipo" => "MULTIMEDIAFIGURA"
          "mostrarFloat" => true
          "mostrarDisplay" => false
          "figura" => array:1 [
            0 => array:4 [
              "imagen" => "gr1.jpeg"
              "Alto" => 3526
              "Ancho" => 3170
              "Tamanyo" => 690413
            ]
          ]
          "descripcion" => array:1 [
            "en" => "<p id="spar0015" class="elsevierStyleSimplePara elsevierViewall">Recommended algorithm for treating the brain-dead organ donor&#46; BD&#44; brain death&#59; CVC&#44; central venous catheter&#59; CVP&#44; central venous pressure&#59; DI&#44; diabetes insipidous&#59; Hb&#44; hemoglobin&#59; IV&#44; intravenous&#59; MAP&#44; median arterial pressure&#59; NA&#44; noradrenaline&#46;</p>"
          ]
        ]
      ]
      "autores" => array:1 [
        0 => array:2 [
          "autoresLista" => "C&#46; Chamorro-Jambrina, M&#46;R&#46; Mu&#241;oz-Ram&#237;rez, J&#46;L&#46; Mart&#237;nez-Melgar, M&#46;S&#46; P&#233;rez-Cornejo"
          "autores" => array:4 [
            0 => array:2 [
              "nombre" => "C&#46;"
              "apellidos" => "Chamorro-Jambrina"
            ]
            1 => array:2 [
              "nombre" => "M&#46;R&#46;"
              "apellidos" => "Mu&#241;oz-Ram&#237;rez"
            ]
            2 => array:2 [
              "nombre" => "J&#46;L&#46;"
              "apellidos" => "Mart&#237;nez-Melgar"
            ]
            3 => array:2 [
              "nombre" => "M&#46;S&#46;"
              "apellidos" => "P&#233;rez-Cornejo"
            ]
          ]
        ]
      ]
    ]
    "idiomaDefecto" => "en"
    "Traduccion" => array:1 [
      "en" => array:9 [
        "pii" => "S2173572717302023"
        "doi" => "10.1016/j.medine.2017.01.008"
        "estado" => "S300"
        "subdocumento" => ""
        "abierto" => array:3 [
          "ES" => true
          "ES2" => true
          "LATM" => true
        ]
        "gratuito" => true
        "lecturas" => array:1 [
          "total" => 0
        ]
        "idiomaDefecto" => "en"
        "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S2173572717302023?idApp=WMIE"
      ]
    ]
    "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0210569117300669?idApp=WMIE"
    "url" => "/02105691/0000004100000009/v1_201711250711/S0210569117300669/v1_201711250711/en/main.assets"
  ]
  "es" => array:14 [
    "idiomaDefecto" => true
    "cabecera" => "<span class="elsevierStyleTextfn">CARTA CIENT&#205;FICA</span>"
    "titulo" => "Evaluaci&#243;n de la fiabilidad de los dispositivos aceler&#243;metros de retroalimentaci&#243;n inmediata en funci&#243;n de la superficie en la que se realice la reanimaci&#243;n cardiopulmonar"
    "tieneTextoCompleto" => true
    "saludo" => "<span class="elsevierStyleItalic">Sr&#46; Editor&#58;</span>"
    "paginas" => array:1 [
      0 => array:2 [
        "paginaInicial" => "569"
        "paginaFinal" => "570"
      ]
    ]
    "autores" => array:1 [
      0 => array:4 [
        "autoresLista" => "M&#46; Freire Tellado, R&#46; Navarro Pat&#243;n, M&#46;P&#46; Pav&#243;n Prieto, J&#46;D&#46; V&#225;zquez L&#243;pez, J&#46; Mateos Lorenzo, M&#46;A&#46; Neira P&#225;jaro"
        "autores" => array:6 [
          0 => array:3 [
            "nombre" => "M&#46;"
            "apellidos" => "Freire Tellado"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          1 => array:4 [
            "nombre" => "R&#46;"
            "apellidos" => "Navarro Pat&#243;n"
            "email" => array:1 [
              0 => "ruben&#46;navarro&#46;paton&#64;usc&#46;es"
            ]
            "referencia" => array:2 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">b</span>"
                "identificador" => "aff0010"
              ]
              1 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">&#42;</span>"
                "identificador" => "cor0005"
              ]
            ]
          ]
          2 => array:3 [
            "nombre" => "M&#46;P&#46;"
            "apellidos" => "Pav&#243;n Prieto"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">a</span>"
                "identificador" => "aff0005"
              ]
            ]
          ]
          3 => array:3 [
            "nombre" => "J&#46;D&#46;"
            "apellidos" => "V&#225;zquez L&#243;pez"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">c</span>"
                "identificador" => "aff0015"
              ]
            ]
          ]
          4 => array:3 [
            "nombre" => "J&#46;"
            "apellidos" => "Mateos Lorenzo"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">d</span>"
                "identificador" => "aff0020"
              ]
            ]
          ]
          5 => array:3 [
            "nombre" => "M&#46;A&#46;"
            "apellidos" => "Neira P&#225;jaro"
            "referencia" => array:1 [
              0 => array:2 [
                "etiqueta" => "<span class="elsevierStyleSup">e</span>"
                "identificador" => "aff0025"
              ]
            ]
          ]
        ]
        "afiliaciones" => array:5 [
          0 => array:3 [
            "entidad" => "M&#233;dico del Servicio de Emergencias M&#233;dicas de la Fundaci&#243;n P&#250;blica Urgencias Sanitarias 061&#44; Base 061 Lugo&#44; Centro de Salud de Fingoy&#44; Lugo&#44; Espa&#241;a"
            "etiqueta" => "a"
            "identificador" => "aff0005"
          ]
          1 => array:3 [
            "entidad" => "Docente de la Facultad de Formaci&#243;n de Profesorado&#44; Universidad de Santiago de Compostela&#44; Lugo&#44; Espa&#241;a"
            "etiqueta" => "b"
            "identificador" => "aff0010"
          ]
          2 => array:3 [
            "entidad" => "Enfermero del Servicio de Emergencias M&#233;dicas de la Fundaci&#243;n P&#250;blica Urgencias Sanitarias 061&#44; Base 061 Foz&#44; Lugo&#44; Espa&#241;a"
            "etiqueta" => "c"
            "identificador" => "aff0015"
          ]
          3 => array:3 [
            "entidad" => "T&#233;cnico del Servicio de Emergencias M&#233;dicas de la Fundaci&#243;n P&#250;blica Urgencias Sanitarias 061&#44; Base 061 Lugo&#44; Centro de Salud de Fingoy&#44; Lugo&#44; Espa&#241;a"
            "etiqueta" => "d"
            "identificador" => "aff0020"
          ]
          4 => array:3 [
            "entidad" => "T&#233;cnico del Servicio de Emergencias M&#233;dicas de la Fundaci&#243;n P&#250;blica Urgencias Sanitarias 061&#44; Base 061 Foz&#44; Lugo&#44; Espa&#241;a"
            "etiqueta" => "e"
            "identificador" => "aff0025"
          ]
        ]
        "correspondencia" => array:1 [
          0 => array:3 [
            "identificador" => "cor0005"
            "etiqueta" => "&#8270;"
            "correspondencia" => "Autor para correspondencia&#46;"
          ]
        ]
      ]
    ]
    "titulosAlternativos" => array:1 [
      "en" => array:1 [
        "titulo" => "Assessment of the reliability of the accelerometers feedback devices depending on the surface on which cardiopulmonary resuscitation is performed"
      ]
    ]
    "textoCompleto" => "<span class="elsevierStyleSections"><p id="par0010" class="elsevierStylePara elsevierViewall">Las actuales gu&#237;as del Consejo Europeo de Resucitaci&#243;n 2015<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a> recomiendan que&#44; cuando sea posible&#44; la RCP debe ser llevada a cabo en superficies duras&#44; y en caso contrario&#44; la recomendaci&#243;n es favorable al uso de tablero duro &#40;tablero espinal&#41;<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a> con la precauci&#243;n de minimizar&#44; en su colocaci&#243;n&#44; las interrupciones en la RCP y la retirada inadvertida de los accesos intravenosos y de los dispositivos de aislamiento de v&#237;a a&#233;rea avanzada&#46;</p><p id="par0015" class="elsevierStylePara elsevierViewall">Sobre la utilizaci&#243;n de dispositivos de retroalimentaci&#243;n de RCP&#44; las actuales gu&#237;as<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a> recomiendan que su uso&#44; solo debe ser considerado como una parte de un sistema m&#225;s amplio de cuidados&#46; Los estudios al respecto<a class="elsevierStyleCrossRef" href="#bib0060"><span class="elsevierStyleSup">2</span></a>&#44; a pesar de no haber demostrado una mejora significativa de la supervivencia al alta hospitalaria&#44; s&#237; han demostrado mejorar significativamente el porcentaje de recuperaci&#243;n de circulaci&#243;n espont&#225;nea en RCP en hospital cuando su uso se combina con un sistema de mejora a trav&#233;s de entrenamiento y sesiones de debriefing&#46;</p><p id="par0020" class="elsevierStylePara elsevierViewall">A pesar de que varios estudios relacionando superficies el&#225;sticas y su influencia en la profundidad de las compresiones<a class="elsevierStyleCrossRefs" href="#bib0065"><span class="elsevierStyleSup">3&#8211;5</span></a> alertan de la influencia negativa de la utilizaci&#243;n de dispositivos aceler&#243;metros cuando son utilizados en diversas superficies el&#225;sticas de uso com&#250;n en hospitales&#44; la utilizaci&#243;n de estos dispositivos se ha extendido entre los sistemas de emergencias m&#233;dicas extrahospitalarios y se han convertido en un elemento de toma de datos en estudios de RCP tanto extra- como intrahospitalaria<a class="elsevierStyleCrossRefs" href="#bib0080"><span class="elsevierStyleSup">6&#44;7</span></a>&#44; los cuales han aportado nueva informaci&#243;n respecto a la relaci&#243;n entre profundidad de las compresiones y supervivencia en la RCP&#46;</p><p id="par0025" class="elsevierStylePara elsevierViewall">Para comprobar si el efecto de distorsi&#243;n en la gu&#237;a de la RCP en las superficies el&#225;sticas de las camas de hospital se reproduc&#237;a tambi&#233;n en las camillas de las ambulancias&#44; se llev&#243; a cabo un estudio con el objetivo espec&#237;fico de evaluar la fiabilidad del dispositivo aceler&#243;metro de feed-back Philips&#44; HeartStart Mrx Q&#8211;CPR&#8482; &#40;Q-CPR&#41; cuando es utilizado como elemento de gu&#237;a de RCP en maniqu&#237; por el personal de un sistema de emergencias m&#233;dicas en 3 superficies&#44; suelo&#44; cama y la espec&#237;fica de camilla de ambulancia&#46;</p><p id="par0030" class="elsevierStylePara elsevierViewall">Colaboraron 16 voluntarios &#40;11 hombres &#91;68&#44;75&#37;&#93; y 5 mujeres &#91;31&#44;25&#37;&#93;&#41;&#44; m&#233;dicos&#44; enfermeros y t&#233;cnicos de emergencias sanitarias del SEM FPUS 061 de Lugo&#44; utilizando para las simulaciones un maniqu&#237; skill reporter de Leardal con dispositivo de control girosc&#243;pico&#44; siguiendo la retroalimentaci&#243;n del dispositivo Q-CPR durante 2 min de compresiones tor&#225;cicas continuas sobre una cama est&#225;ndar de hospital con colch&#243;n &#40;190 largo x 90 ancho x 19<span class="elsevierStyleHsp" style=""></span>cm de espesor&#41;&#44; sobre una camilla de traslado de ambulancia promeba 6107 en bancada de 57<span class="elsevierStyleHsp" style=""></span>cm de altura con colch&#243;n &#40;190<span class="elsevierStyleHsp" style=""></span>&#215;<span class="elsevierStyleHsp" style=""></span>48<span class="elsevierStyleHsp" style=""></span>&#215;<span class="elsevierStyleHsp" style=""></span>9<span class="elsevierStyleHsp" style=""></span>cm&#41; y sobre una superficie no el&#225;stica &#40;suelo&#41;&#46; La variable de resultado principal fue la diferencia de profundidad &#40;diferencia entre los par&#225;metros recogidos por el Q-CPR y el aceler&#243;metro del Maniqu&#237; skill reporter&#41; en cada una de las tres superficies&#46;</p><p id="par0035" class="elsevierStylePara elsevierViewall">Los an&#225;lisis estad&#237;sticos se realizaron con SPSS para Windows&#44; versi&#243;n 20&#46; El test de Kolmogorov-Smirnov fue realizado para el estudio de la normalidad y para comprobar la diferencia de medias entre las diferentes superficies se realiz&#243; un ANOVA de un factor con las pruebas post-hoc de Bonferroni&#46;</p><p id="par0040" class="elsevierStylePara elsevierViewall">La profundidad media de las compresiones recogida por el aceler&#243;metro Q-CPR comparada con el registro girosc&#243;pico fue de 51&#44;68<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 6&#44;11&#41; &#40;rango 43-62<span class="elsevierStyleHsp" style=""></span>mm&#41; vs&#46; 56&#44;06<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 5&#44;05&#41; &#40;rango 46-63<span class="elsevierStyleHsp" style=""></span>mm&#41; en el suelo&#44; de 54&#44;93<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 7&#44;88&#41; &#40;rango 43-69<span class="elsevierStyleHsp" style=""></span>mm&#41; vs&#46; 45&#44;12<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 4&#44;88&#41; &#40;rango 35-54<span class="elsevierStyleHsp" style=""></span>mm&#41; en la camilla de la ambulancia y de 57&#44;18<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 10&#44;79&#41; &#40;rango 40 a 78<span class="elsevierStyleHsp" style=""></span>mm&#41; vs&#46; 31&#44;12<span class="elsevierStyleHsp" style=""></span>mm &#40;DE 4&#44;16&#41; &#40;rango 24-42<span class="elsevierStyleHsp" style=""></span>mm&#41; en la cama&#46; Las diferencias de profundidad media en<span class="elsevierStyleHsp" style=""></span>mm entre los 2 m&#233;todos de registro en las 3 superficies fueron&#58; M <span class="elsevierStyleInf">Suelo</span>&#61; -4&#44;41 &#40;<span class="elsevierStyleItalic">DT</span> 7&#44;34&#41;&#59; M <span class="elsevierStyleInf">Camilla</span><span class="elsevierStyleHsp" style=""></span>&#61;<span class="elsevierStyleHsp" style=""></span>9&#44;81 &#40;<span class="elsevierStyleItalic">DT</span> 5&#44;92&#41; M <span class="elsevierStyleInf">Cama</span>&#61; 26&#44;06 &#40;<span class="elsevierStyleItalic">DT</span> 9&#44;39&#41; consider&#225;ndose estad&#237;sticamente significativas en las 3 superficies &#40;F <span class="elsevierStyleInf">&#40;2&#44;45&#41;</span> &#61;62&#44;38 &#40;p<span class="elsevierStyleHsp" style=""></span>&#60;<span class="elsevierStyleHsp" style=""></span>0&#44;001&#41;&#44; Eta<span class="elsevierStyleSup">2</span>&#61; 0&#44;7349&#41;&#46;</p><p id="par0045" class="elsevierStylePara elsevierViewall">Se produjo un reiterado incumplimiento en el objetivo de seguir las indicaciones del dispositivo por parte de los participantes&#44; profesionales sanitarios acostumbrados a realizar compresiones card&#237;acas en v&#237;ctimas reales&#58; la impresi&#243;n subjetiva de estar realizando un masaje de escasa profundidad provocaba abandono en el seguimiento del dispositivo&#44; este abandono aumentaba conforme se incrementaba el espesor de la superficie el&#225;stica en la que se llevaban a cabo las compresiones&#46;</p><p id="par0050" class="elsevierStylePara elsevierViewall">El aceler&#243;metro fue adecuado como gu&#237;a de la calidad de las compresiones cuando fue utilizado en una superficie dura &#40;suelo&#41;&#44; pero no en las superficies el&#225;sticas ya que las indicaciones del aparato suger&#237;an que se estaban realizando compresiones card&#237;acas de profundidad correcta&#44; pero esta&#44; en realidad&#44; estaba por debajo de los l&#237;mites recomendados en las gu&#237;as de RCP<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a>&#46; Este efecto se produjo debido a la inercia de la baja resistencia de la superficie el&#225;stica y se relacion&#243; con el espesor de la superficie el&#225;stica&#58; a mayor espesor&#44; mayores eran los errores en la profundidad&#46;</p><p id="par0055" class="elsevierStylePara elsevierViewall">Este estudio&#44; a pesar de lo reducido de la muestra&#44; lo que hace es que estos resultados no puedan ser generalizables&#44; obtiene resultados similares a estudios previos con aceler&#243;metros en superficies el&#225;sticas de uso com&#250;n en hospital&#44; mostrando resultados similares a otros estudios<a class="elsevierStyleCrossRef" href="#bib0065"><span class="elsevierStyleSup">3</span></a> y con menor concordancia con estudios con calibraci&#243;n previa<a class="elsevierStyleCrossRefs" href="#bib0070"><span class="elsevierStyleSup">4&#44;5</span></a>&#46;</p><p id="par0060" class="elsevierStylePara elsevierViewall">Recientes estudios ofrecen resultados prometedores para nuevos dispositivos de retroalimentaci&#243;n que no se ven afectados por la resistencia el&#225;stica como son los dispositivos girosc&#243;picos<a class="elsevierStyleCrossRef" href="#bib0070"><span class="elsevierStyleSup">4</span></a> y los sensores flexibles de presi&#243;n &#40;Shinnosekuken&#41;<a class="elsevierStyleCrossRefs" href="#bib0090"><span class="elsevierStyleSup">8&#44;9</span></a> y de las potenciales ventajas del uso de los dispositivos mec&#225;nicos de compresi&#243;n card&#237;aca<a class="elsevierStyleCrossRef" href="#bib0100"><span class="elsevierStyleSup">10</span></a> sobre el operador humano especialmente en superficies el&#225;sticas&#44; pero hasta el momento&#44; probablemente se deber&#237;a reforzar la recomendaci&#243;n del Consejo Europeo de Resucitaci&#243;n<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a>&#44; de realizar las compresiones tor&#225;cicas en una superficie dura cuando fuera posible y desarrollar protocolos espec&#237;ficos con el uso de estos nuevos dispositivos prometedores para aquellos servicios en que por sus especiales caracter&#237;sticas no pudieran mantener una calidad alta de las compresiones<a class="elsevierStyleCrossRef" href="#bib0055"><span class="elsevierStyleSup">1</span></a> y siempre como parte de un sistema integral de cuidados<a class="elsevierStyleCrossRef" href="#bib0060"><span class="elsevierStyleSup">2</span></a>&#46;</p><p id="par0065" class="elsevierStylePara elsevierViewall">En resumen&#44; el aceler&#243;metro Q-CPR ofreci&#243; una retroalimentaci&#243;n para la gu&#237;a fiable cuando fue usado como dispositivo en superficies duras&#44; pero no en superficies que presentan cierto grado de elasticidad como camas y camillas de ambulancia&#44; en las cuales su uso deber&#237;a de ser evitado&#46;</p><span id="sec0005" class="elsevierStyleSection elsevierViewall"><span class="elsevierStyleSectionTitle" id="sect0005">Autor&#237;a&#47;colaboradores</span><p id="par0070" class="elsevierStylePara elsevierViewall">Todos los autores han participado en todas las partes del trabajo de investigaci&#243;n y en la preparaci&#243;n del art&#237;culo &#40;en la concepci&#243;n y el dise&#241;o del estudio&#44; en la adquisici&#243;n de datos&#44; en el an&#225;lisis y la interpretaci&#243;n de los datos&#44; as&#237; como en el borrador del art&#237;culo&#44; la revisi&#243;n cr&#237;tica del contenido intelectual&#44; y en la aprobaci&#243;n definitiva de este documento&#41;&#46;</p></span></span>"
    "textoCompletoSecciones" => array:1 [
      "secciones" => array:3 [
        0 => array:2 [
          "identificador" => "sec0005"
          "titulo" => "Autor&#237;a&#47;colaboradores"
        ]
        1 => array:2 [
          "identificador" => "xack319688"
          "titulo" => "Agradecimientos"
        ]
        2 => array:1 [
          "titulo" => "Bibliograf&#237;a"
        ]
      ]
    ]
    "pdfFichero" => "main.pdf"
    "tienePdf" => true
    "bibliografia" => array:2 [
      "titulo" => "Bibliograf&#237;a"
      "seccion" => array:1 [
        0 => array:2 [
          "identificador" => "bibs0015"
          "bibliografiaReferencia" => array:10 [
            0 => array:3 [
              "identificador" => "bib0055"
              "etiqueta" => "1"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "European Resuscitation Council Summary of the main changes in the Resuscitation Guidelines"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "L&#46; Bossaert"
                            1 => "R&#46; Greif"
                            2 => "I&#46; Maconochie"
                            3 => "K&#46;G&#46; Monsieurs"
                            4 => "N&#46; Nikolaou"
                            5 => "J&#46;P&#46; Nolan"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:6 [
                        "tituloSerie" => "Resuscitation"
                        "fecha" => "2015"
                        "volumen" => "95"
                        "paginaInicial" => "201"
                        "paginaFinal" => "221"
                        "itemHostRev" => array:3 [
                          "pii" => "S0140673614604098"
                          "estado" => "S300"
                          "issn" => "01406736"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            1 => array:3 [
              "identificador" => "bib0060"
              "etiqueta" => "2"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Improving in-hospital cardiac arrest process and outcomes with performance debriefing"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "D&#46;P&#46; Edelson"
                            1 => "B&#46; Litzinger"
                            2 => "V&#46; Arora"
                            3 => "D&#46; Walsh"
                            4 => "S&#46; Kim"
                            5 => "D&#46;S&#46; Lauderdale"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1001/archinte.168.10.1063"
                      "Revista" => array:6 [
                        "tituloSerie" => "Arch Intern Med&#46;"
                        "fecha" => "2008"
                        "volumen" => "168"
                        "paginaInicial" => "1063"
                        "paginaFinal" => "1069"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/18504334"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            2 => array:3 [
              "identificador" => "bib0065"
              "etiqueta" => "3"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Compression feedback devices over estimate chest compression depth when performed on a bed"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:5 [
                            0 => "G&#46;D&#46; Perkins"
                            1 => "L&#46; Kocierz"
                            2 => "S&#46;C&#46;L&#46; Smith"
                            3 => "R&#46;A&#46; McCulloch"
                            4 => "R&#46;P&#46; Davies"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:1 [
                      "Revista" => array:5 [
                        "tituloSerie" => "Resuscitation"
                        "fecha" => "2009"
                        "volumen" => "80"
                        "paginaInicial" => "78"
                        "paginaFinal" => "82"
                      ]
                    ]
                  ]
                ]
              ]
            ]
            3 => array:3 [
              "identificador" => "bib0070"
              "etiqueta" => "4"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Accurate feedback of chest compression depth on a manikin on a soft surface with correctionfor total body displacement"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:2 [
                            0 => "S&#46;G&#46; Beesems"
                            1 => "R&#46;W&#46; Koster"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.resuscitation.2014.08.005"
                      "Revista" => array:7 [
                        "tituloSerie" => "Resuscitation"
                        "fecha" => "2014"
                        "volumen" => "85"
                        "paginaInicial" => "1439"
                        "paginaFinal" => "1443"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25150184"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0140673614604098"
                          "estado" => "S300"
                          "issn" => "01406736"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            4 => array:3 [
              "identificador" => "bib0075"
              "etiqueta" => "5"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Effect of mattress and bed frame deflection on real chest compression depth measured with two CPR sensors"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "M&#46; Sainio"
                            1 => "H&#46; Hellevuo"
                            2 => "H&#46; Huhtala"
                            3 => "S&#46; Hoppu"
                            4 => "J&#46; Eilevstj&#248;nn"
                            5 => "J&#46; Tenhunen"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.resuscitation.2014.03.009"
                      "Revista" => array:6 [
                        "tituloSerie" => "Resuscitation"
                        "fecha" => "2014"
                        "volumen" => "85"
                        "paginaInicial" => "840"
                        "paginaFinal" => "843"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/24657249"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            5 => array:3 [
              "identificador" => "bib0080"
              "etiqueta" => "6"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Resuscitation Outcomes Consortium Investigators What is the optimal chest compression depth during out-of-hospital cardiac arrest resuscitation of adults patients&#63;"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "I&#46;G&#46; Stiell"
                            1 => "S&#46;P&#46; Brow"
                            2 => "G&#46; Nichol"
                            3 => "S&#46; Cheskes"
                            4 => "C&#46; Vaillancourt"
                            5 => "C&#46;W&#46; Callaway"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1161/CIRCULATIONAHA.114.008671"
                      "Revista" => array:6 [
                        "tituloSerie" => "Circulation"
                        "fecha" => "2014"
                        "volumen" => "130"
                        "paginaInicial" => "1962"
                        "paginaFinal" => "1970"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/25252721"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            6 => array:3 [
              "identificador" => "bib0085"
              "etiqueta" => "7"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Deeper chest compression&#8211;more complications for cardiac arrest patients"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "H&#46; Hellevuo"
                            1 => "M&#46; Sainio"
                            2 => "R&#46; Nevalinen"
                            3 => "H&#46; Huhtala"
                            4 => "K&#46;T&#46; Olkkola"
                            5 => "J&#46; Tenhunen"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.resuscitation.2013.02.015"
                      "Revista" => array:6 [
                        "tituloSerie" => "Resuscitation"
                        "fecha" => "2013"
                        "volumen" => "84"
                        "paginaInicial" => "760"
                        "paginaFinal" => "765"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23474390"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            7 => array:3 [
              "identificador" => "bib0090"
              "etiqueta" => "8"
              "referencia" => array:1 [
                0 => array:3 [
                  "comentario" => "&#40;En prensa&#41;"
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Analysis of actual pressure point using the power flexible capacitive sensor during chest compression"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "K&#46; Minami"
                            1 => "Y&#46; Kokubo"
                            2 => "I&#46; Maeda"
                            3 => "S&#46; Hibino"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1007/s00540-016-2265-3"
                      "Revista" => array:3 [
                        "tituloSerie" => "J Anesth"
                        "fecha" => "2016"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/23839898"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            8 => array:3 [
              "identificador" => "bib0095"
              "etiqueta" => "9"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "A flexible pressure sensor could correctly measure the depth of chest compression on a mattress"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => false
                          "autores" => array:4 [
                            0 => "K&#46; Minami"
                            1 => "Y&#46; Kokubo"
                            2 => "I&#46; Maeda"
                            3 => "S&#46; Hibino"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.ajem.2016.02.052"
                      "Revista" => array:6 [
                        "tituloSerie" => "Am J Emerg Med"
                        "fecha" => "2016"
                        "volumen" => "34"
                        "paginaInicial" => "899"
                        "paginaFinal" => "902"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26979259"
                            "web" => "Medline"
                          ]
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
            9 => array:3 [
              "identificador" => "bib0100"
              "etiqueta" => "10"
              "referencia" => array:1 [
                0 => array:2 [
                  "contribucion" => array:1 [
                    0 => array:2 [
                      "titulo" => "Manual versus mechanical chest compressions on surfaces of varying softness with or without backboards&#58; A randomized&#44; crossover manikin study"
                      "autores" => array:1 [
                        0 => array:2 [
                          "etal" => true
                          "autores" => array:6 [
                            0 => "G&#46; Putzer"
                            1 => "A&#46; Fiala"
                            2 => "P&#46; Braun"
                            3 => "S&#46; Neururer"
                            4 => "K&#46; Biechl"
                            5 => "B&#46; Keilig"
                          ]
                        ]
                      ]
                    ]
                  ]
                  "host" => array:1 [
                    0 => array:2 [
                      "doi" => "10.1016/j.jemermed.2015.10.002"
                      "Revista" => array:7 [
                        "tituloSerie" => "J Emerg Med"
                        "fecha" => "2016"
                        "volumen" => "50"
                        "paginaInicial" => "594"
                        "paginaFinal" => "600"
                        "link" => array:1 [
                          0 => array:2 [
                            "url" => "https://www.ncbi.nlm.nih.gov/pubmed/26607696"
                            "web" => "Medline"
                          ]
                        ]
                        "itemHostRev" => array:3 [
                          "pii" => "S0140673612620893"
                          "estado" => "S300"
                          "issn" => "01406736"
                        ]
                      ]
                    ]
                  ]
                ]
              ]
            ]
          ]
        ]
      ]
    ]
    "agradecimientos" => array:1 [
      0 => array:4 [
        "identificador" => "xack319688"
        "titulo" => "Agradecimientos"
        "texto" => "<p id="par0075" class="elsevierStylePara elsevierViewall">Se agradece a los m&#233;dicos&#44; enfermeros y t&#233;cnicos en emergencias su participaci&#243;n altruista en este estudio&#46;</p>"
        "vista" => "all"
      ]
    ]
  ]
  "idiomaDefecto" => "es"
  "url" => "/02105691/0000004100000009/v1_201711250711/S0210569117302061/v1_201711250711/es/main.assets"
  "Apartado" => array:4 [
    "identificador" => "19505"
    "tipo" => "SECCION"
    "es" => array:2 [
      "titulo" => "Cartas Cient&#237;ficas"
      "idiomaDefecto" => true
    ]
    "idiomaDefecto" => "es"
  ]
  "PDF" => "https://static.elsevier.es/multimedia/02105691/0000004100000009/v1_201711250711/S0210569117302061/v1_201711250711/es/main.pdf?idApp=WMIE&text.app=https://medintensiva.org/"
  "EPUB" => "https://multimedia.elsevier.es/PublicationsMultimediaV1/item/epub/S0210569117302061?idApp=WMIE"
]
Compartir
Información de la revista
Vol. 41. Núm. 9.
Páginas 569-570 (diciembre 2017)
Vol. 41. Núm. 9.
Páginas 569-570 (diciembre 2017)
CARTA CIENTÍFICA
Acceso a texto completo
Evaluación de la fiabilidad de los dispositivos acelerómetros de retroalimentación inmediata en función de la superficie en la que se realice la reanimación cardiopulmonar
Assessment of the reliability of the accelerometers feedback devices depending on the surface on which cardiopulmonary resuscitation is performed
Visitas
9786
M. Freire Telladoa, R. Navarro Patónb,
Autor para correspondencia
ruben.navarro.paton@usc.es

Autor para correspondencia.
, M.P. Pavón Prietoa, J.D. Vázquez Lópezc, J. Mateos Lorenzod, M.A. Neira Pájaroe
a Médico del Servicio de Emergencias Médicas de la Fundación Pública Urgencias Sanitarias 061, Base 061 Lugo, Centro de Salud de Fingoy, Lugo, España
b Docente de la Facultad de Formación de Profesorado, Universidad de Santiago de Compostela, Lugo, España
c Enfermero del Servicio de Emergencias Médicas de la Fundación Pública Urgencias Sanitarias 061, Base 061 Foz, Lugo, España
d Técnico del Servicio de Emergencias Médicas de la Fundación Pública Urgencias Sanitarias 061, Base 061 Lugo, Centro de Salud de Fingoy, Lugo, España
e Técnico del Servicio de Emergencias Médicas de la Fundación Pública Urgencias Sanitarias 061, Base 061 Foz, Lugo, España
Este artículo ha recibido
Información del artículo
Texto completo
Bibliografía
Descargar PDF
Estadísticas
Texto completo
Sr. Editor:

Las actuales guías del Consejo Europeo de Resucitación 20151 recomiendan que, cuando sea posible, la RCP debe ser llevada a cabo en superficies duras, y en caso contrario, la recomendación es favorable al uso de tablero duro (tablero espinal)1 con la precaución de minimizar, en su colocación, las interrupciones en la RCP y la retirada inadvertida de los accesos intravenosos y de los dispositivos de aislamiento de vía aérea avanzada.

Sobre la utilización de dispositivos de retroalimentación de RCP, las actuales guías1 recomiendan que su uso, solo debe ser considerado como una parte de un sistema más amplio de cuidados. Los estudios al respecto2, a pesar de no haber demostrado una mejora significativa de la supervivencia al alta hospitalaria, sí han demostrado mejorar significativamente el porcentaje de recuperación de circulación espontánea en RCP en hospital cuando su uso se combina con un sistema de mejora a través de entrenamiento y sesiones de debriefing.

A pesar de que varios estudios relacionando superficies elásticas y su influencia en la profundidad de las compresiones3–5 alertan de la influencia negativa de la utilización de dispositivos acelerómetros cuando son utilizados en diversas superficies elásticas de uso común en hospitales, la utilización de estos dispositivos se ha extendido entre los sistemas de emergencias médicas extrahospitalarios y se han convertido en un elemento de toma de datos en estudios de RCP tanto extra- como intrahospitalaria6,7, los cuales han aportado nueva información respecto a la relación entre profundidad de las compresiones y supervivencia en la RCP.

Para comprobar si el efecto de distorsión en la guía de la RCP en las superficies elásticas de las camas de hospital se reproducía también en las camillas de las ambulancias, se llevó a cabo un estudio con el objetivo específico de evaluar la fiabilidad del dispositivo acelerómetro de feed-back Philips, HeartStart Mrx Q–CPR™ (Q-CPR) cuando es utilizado como elemento de guía de RCP en maniquí por el personal de un sistema de emergencias médicas en 3 superficies, suelo, cama y la específica de camilla de ambulancia.

Colaboraron 16 voluntarios (11 hombres [68,75%] y 5 mujeres [31,25%]), médicos, enfermeros y técnicos de emergencias sanitarias del SEM FPUS 061 de Lugo, utilizando para las simulaciones un maniquí skill reporter de Leardal con dispositivo de control giroscópico, siguiendo la retroalimentación del dispositivo Q-CPR durante 2 min de compresiones torácicas continuas sobre una cama estándar de hospital con colchón (190 largo x 90 ancho x 19cm de espesor), sobre una camilla de traslado de ambulancia promeba 6107 en bancada de 57cm de altura con colchón (190×48×9cm) y sobre una superficie no elástica (suelo). La variable de resultado principal fue la diferencia de profundidad (diferencia entre los parámetros recogidos por el Q-CPR y el acelerómetro del Maniquí skill reporter) en cada una de las tres superficies.

Los análisis estadísticos se realizaron con SPSS para Windows, versión 20. El test de Kolmogorov-Smirnov fue realizado para el estudio de la normalidad y para comprobar la diferencia de medias entre las diferentes superficies se realizó un ANOVA de un factor con las pruebas post-hoc de Bonferroni.

La profundidad media de las compresiones recogida por el acelerómetro Q-CPR comparada con el registro giroscópico fue de 51,68mm (DE 6,11) (rango 43-62mm) vs. 56,06mm (DE 5,05) (rango 46-63mm) en el suelo, de 54,93mm (DE 7,88) (rango 43-69mm) vs. 45,12mm (DE 4,88) (rango 35-54mm) en la camilla de la ambulancia y de 57,18mm (DE 10,79) (rango 40 a 78mm) vs. 31,12mm (DE 4,16) (rango 24-42mm) en la cama. Las diferencias de profundidad media enmm entre los 2 métodos de registro en las 3 superficies fueron: M Suelo= -4,41 (DT 7,34); M Camilla=9,81 (DT 5,92) M Cama= 26,06 (DT 9,39) considerándose estadísticamente significativas en las 3 superficies (F (2,45) =62,38 (p<0,001), Eta2= 0,7349).

Se produjo un reiterado incumplimiento en el objetivo de seguir las indicaciones del dispositivo por parte de los participantes, profesionales sanitarios acostumbrados a realizar compresiones cardíacas en víctimas reales: la impresión subjetiva de estar realizando un masaje de escasa profundidad provocaba abandono en el seguimiento del dispositivo, este abandono aumentaba conforme se incrementaba el espesor de la superficie elástica en la que se llevaban a cabo las compresiones.

El acelerómetro fue adecuado como guía de la calidad de las compresiones cuando fue utilizado en una superficie dura (suelo), pero no en las superficies elásticas ya que las indicaciones del aparato sugerían que se estaban realizando compresiones cardíacas de profundidad correcta, pero esta, en realidad, estaba por debajo de los límites recomendados en las guías de RCP1. Este efecto se produjo debido a la inercia de la baja resistencia de la superficie elástica y se relacionó con el espesor de la superficie elástica: a mayor espesor, mayores eran los errores en la profundidad.

Este estudio, a pesar de lo reducido de la muestra, lo que hace es que estos resultados no puedan ser generalizables, obtiene resultados similares a estudios previos con acelerómetros en superficies elásticas de uso común en hospital, mostrando resultados similares a otros estudios3 y con menor concordancia con estudios con calibración previa4,5.

Recientes estudios ofrecen resultados prometedores para nuevos dispositivos de retroalimentación que no se ven afectados por la resistencia elástica como son los dispositivos giroscópicos4 y los sensores flexibles de presión (Shinnosekuken)8,9 y de las potenciales ventajas del uso de los dispositivos mecánicos de compresión cardíaca10 sobre el operador humano especialmente en superficies elásticas, pero hasta el momento, probablemente se debería reforzar la recomendación del Consejo Europeo de Resucitación1, de realizar las compresiones torácicas en una superficie dura cuando fuera posible y desarrollar protocolos específicos con el uso de estos nuevos dispositivos prometedores para aquellos servicios en que por sus especiales características no pudieran mantener una calidad alta de las compresiones1 y siempre como parte de un sistema integral de cuidados2.

En resumen, el acelerómetro Q-CPR ofreció una retroalimentación para la guía fiable cuando fue usado como dispositivo en superficies duras, pero no en superficies que presentan cierto grado de elasticidad como camas y camillas de ambulancia, en las cuales su uso debería de ser evitado.

Autoría/colaboradores

Todos los autores han participado en todas las partes del trabajo de investigación y en la preparación del artículo (en la concepción y el diseño del estudio, en la adquisición de datos, en el análisis y la interpretación de los datos, así como en el borrador del artículo, la revisión crítica del contenido intelectual, y en la aprobación definitiva de este documento).

Agradecimientos

Se agradece a los médicos, enfermeros y técnicos en emergencias su participación altruista en este estudio.

Bibliografía
[1]
L. Bossaert, R. Greif, I. Maconochie, K.G. Monsieurs, N. Nikolaou, J.P. Nolan, et al.
European Resuscitation Council Summary of the main changes in the Resuscitation Guidelines.
Resuscitation, 95 (2015), pp. 201-221
[2]
D.P. Edelson, B. Litzinger, V. Arora, D. Walsh, S. Kim, D.S. Lauderdale, et al.
Improving in-hospital cardiac arrest process and outcomes with performance debriefing.
Arch Intern Med., 168 (2008), pp. 1063-1069
[3]
G.D. Perkins, L. Kocierz, S.C.L. Smith, R.A. McCulloch, R.P. Davies.
Compression feedback devices over estimate chest compression depth when performed on a bed.
Resuscitation, 80 (2009), pp. 78-82
[4]
S.G. Beesems, R.W. Koster.
Accurate feedback of chest compression depth on a manikin on a soft surface with correctionfor total body displacement.
Resuscitation, 85 (2014), pp. 1439-1443
[5]
M. Sainio, H. Hellevuo, H. Huhtala, S. Hoppu, J. Eilevstjønn, J. Tenhunen, et al.
Effect of mattress and bed frame deflection on real chest compression depth measured with two CPR sensors.
Resuscitation, 85 (2014), pp. 840-843
[6]
I.G. Stiell, S.P. Brow, G. Nichol, S. Cheskes, C. Vaillancourt, C.W. Callaway, et al.
Resuscitation Outcomes Consortium Investigators What is the optimal chest compression depth during out-of-hospital cardiac arrest resuscitation of adults patients?.
Circulation, 130 (2014), pp. 1962-1970
[7]
H. Hellevuo, M. Sainio, R. Nevalinen, H. Huhtala, K.T. Olkkola, J. Tenhunen, et al.
Deeper chest compression–more complications for cardiac arrest patients.
Resuscitation, 84 (2013), pp. 760-765
[8]
K. Minami, Y. Kokubo, I. Maeda, S. Hibino.
Analysis of actual pressure point using the power flexible capacitive sensor during chest compression.
[9]
K. Minami, Y. Kokubo, I. Maeda, S. Hibino.
A flexible pressure sensor could correctly measure the depth of chest compression on a mattress.
Am J Emerg Med, 34 (2016), pp. 899-902
[10]
G. Putzer, A. Fiala, P. Braun, S. Neururer, K. Biechl, B. Keilig, et al.
Manual versus mechanical chest compressions on surfaces of varying softness with or without backboards: A randomized, crossover manikin study.
J Emerg Med, 50 (2016), pp. 594-600
Copyright © 2017. Elsevier España, S.L.U. y SEMICYUC
Descargar PDF
Idiomas
Medicina Intensiva
Opciones de artículo
Herramientas
es en

¿Es usted profesional sanitario apto para prescribir o dispensar medicamentos?

Are you a health professional able to prescribe or dispense drugs?